A Novel Bone Collector Designed for Intraoral Harvesting

Article Preview

Abstract:

Objective:The aim of the article was to systematically evaluate a novel bone collector designed by authors for intraoral harvesting.Method: An electronic combined with a hand literature search was conducted and comparative analysis was performed focusing on the principle,quantity,decontamination and cost between author-designed collector and the one recommended in literature.Result: The collectors recommended in literature all are based on filter principle and contain different size of sieve for collecting bone debris which have the disadvantage of lower bone volumes,suction blocking easily and particularly susceptible to oral microbial contamination.While the bone collector designed by authors is based on dynamics principle and centrifugal separation principle and appeares to be higher efficient,effective decontamination in bone collection and low cost. Conclusion: The principle of the bone collector designed by authors was innovative and will have good application in ordinary native dental clinic for providing efficient osteogenesis,less trauma and less cost.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

384-387

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] J. Jensen, S. Sindet-Pedersen, Autogenous mandibular bone grafts and osseointegrated implants for reconstruction of the severely atrophied maxilla: a preliminary report, J . Oral Maxillofac Surg. 1991. 49(12).

DOI: 10.1016/0278-2391(91)90303-4

Google Scholar

[2] M.P. Young, et al, Bone collected during dental implant surgery: a clinical and histological study, Clin Oral Implants Res. 2002. 13(3).

Google Scholar

[3] C.M. Misch, et al, Reconstruction of maxillary alveolar defects with mandibular symphysis grafts for dental implants: a preliminary procedural report, Int J Oral Maxillofac Implants. 1992. 7(3).

Google Scholar

[4] Y.B. Gao H.C. Sun Y.M. Zhou X.F. Wuand A. Jiang, CN. Patent 20101019787. 0. (2012).

Google Scholar

[5] K.T. Wang, et al, The production and application of a one-off bone collector with two suction tips using in dental implantation,J. Clin Stomatol. 2005. 21(5).

Google Scholar

[6] X. Ding, et al, Bone collector for implant surgery, CN, patent 200820085498. 6. (2009).

Google Scholar

[7] V.T. Kainulainen, et al, Performance of six bone collectors designed for dental implant surgery, Clin Oral Implants Res. 2006. 17(3).

DOI: 10.1111/j.1600-0501.2005.01199.x

Google Scholar

[8] E. Tezulas, and O.C. Dilek, Decontamination of autogenous bone grafts collected from dental implant sites via osteotomy: a review, Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008. 106(5).

DOI: 10.1016/j.tripleo.2008.05.041

Google Scholar

[9] M.P. Young, et al, Microbial analysis of bone collected during implant surgery: a clinical and laboratory study, Clin Oral Implants Res. 2001. 12(2).

DOI: 10.1034/j.1600-0501.2001.012002095.x

Google Scholar

[10] T.D. Savant, et al, Bone volume collected from dental implant sites during osteotomy, J Oral Maxillofac Surg. 2001. 59(8).

Google Scholar