ECG Signal Processing

Article Preview

Abstract:

Electrocardiography (ECG) is a diagnostic method that allows sensing and record the electric activity of heart [. The measurement of electrical activity is used as a standard twelve-point system. At each of these leads to measure the useful signal and interference was measured. The intensity of interference depends on the artefacts (electrical lines, brum, motion artefacts, muscle, interference from the environment, etc.). For correct evaluation of measured signal there is a need to processing the measured signal to suitable form. At present, the use of electrocardiograms with sensors with contact scanning are difficult to set a time so we decided to use the principle of non-contact sensing. Such a device to measure the ECG was constructed under the project. The disadvantage of such devices is a problem with a high level of noise, which degrades a useful signal. The aim of this article is to pre-process the signals obtained from non-contact sensing. The contactless devices are powered from the network and battery. The electrodes were connected by way of Eithoven bipolar leads. Signals were pre-treated with suitable filters so that they are also appropriate for their subsequent analysis. In the filtration ECG signals was used as a method of linear (low pass filter, high pass, IIR (Infinite Impulse Response) peak, notch filter. The results of many signals clearly demonstrate removing noise in the ECG signals to the point that is also suitable for their analysis.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

394-400

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] T. Togowa, T. Tamura, P.A. Oberg: Biomedical TRANSDUCERS and INSTRUMENTS (CRC Press, Florida 1997).

Google Scholar

[2] Heart Rate Variability: Standards of Measuremant, Physiological Interpretation, and Clinical Use. European Heart Journal n. 17, p.354 – 381, (1996).

Google Scholar

[3] L. Smolarik, A. Libosvarova, D. Mudroncik, P. Schreiber: Non-contact ECG Signal Processing (IEEE Publications, Bulgaria, 2012).

DOI: 10.1109/is.2012.6335241

Google Scholar

[4] S. Chavan, A. Agarwala, D. Uplane: Interference Reduction in ECG using Digital FIR Filters based on rectangular window, India, (2011).

Google Scholar

[6] J. Rysanek: Narrow band filtering of ECG signals, Brno, 2010, pp.8-20.

Google Scholar

[7] L. Harika Bommadevara, B. Surya Prasada Rao, P. Rajesh Kumar, P. Rajesh Kumar: Interference Reduction in ECG using Digital FIR Filters, vol. 2 (2011), pp.76-80.

Google Scholar

[8] P. Miscik: Electrocardiogram processing, Brno, (2011).

Google Scholar

[9] Information on http: /www. mathworks. com/help/signal/ref/firpm. html.

Google Scholar

[10] Information on http: /www. mathworks. com/help/dsp/ref/iirnotch. html.

Google Scholar

[11] Information on http: /www. analog. com/static/imported-files/tech_docs/dsp_book_Ch21. pdf.

Google Scholar