Mitigation of Voltage Sags and Swells by Dynamic Voltage Restorer

Article Preview

Abstract:

This paper presents the modelling and simulation of Dynamic Voltage Restorer (DVR) for mitigation of voltage sags and swells which are the major problems and issues on non linear loads.The Dynamic Voltage Restore (DVR) has become popular as a cost effective solutions for the protection of sensitive loads from voltage sags and swells.. The control of compensation voltages in DVR based on a-b-c to d-q-0 algorithm is discussed. The proposed control technique is cost effective and simple to design. Computer simulations are carried out in a suitable test system to investigate the effectiveness of control technique by using MATLAB/SIMULINK software.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

338-343

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Salimin, Rahmatul Hidayah. Simulation Analysis Of Dvr Performance For Voltage sag mitigation, The 5th International Power Engineering and Optimization Conference (PEOCO2011), Shah Alam, Selangor, Malaysia : 6-7 June (2011).

DOI: 10.1109/peoco.2011.5970386

Google Scholar

[2] Ravilla Madhusudan , G. Ramamohan Rao, Modeling and Simulation of a Dynamic Voltage Restorer (DVR) for Power Quality ProblemsVoltage Sags and Swells, IEEE- International Conference On Advances In Engineering, Science And Management (ICAESM -2012) March 30, 31, (2012).

Google Scholar

[3] R. Omar, N. A. Rahim, M. Sulaiman, "Modeling and Simulation for Voltage Sags/Swell Mitigation Using Dynamic Voltage Restorer (DVR), Journal of Theoretical and Applied Information Technology, pp.464-470, 2005-(2009).

Google Scholar

[4] D. Rajasekaran, Dr. Subhransu Sekhar Dash , P. Vignesh, Mitigation Of Voltage Sags And Voltage Swells By Dynamic Voltage Restorer, proc. of Int. Conf on Advances in Recent Technologies in Communication and Computing 20 I I.

DOI: 10.1049/ic.2011.0047

Google Scholar

[5] Khanh, Bach Quoc , Mitigating Voltage Sags Due to DOL Starting of Three Phase Asynchronous Motors Using Dynamic Voltage Restorer (DVR), Transmission and Distribution Conference and Exposition (T&D), 2012 IEEE PES, 7-10 May (2012).

DOI: 10.1109/tdc.2012.6281673

Google Scholar

[6] Roger C. Dugan Electrical Power Systems Quality, TATA McGRAW-HILL EDITION-(2008).

Google Scholar

[7] H. Hingorani, Introducing custom power, IEEE Spectrum, vol. 32, no. 6, pp.41-48, June (1995).

Google Scholar

[8] Practice for Monitoring Electric Power Quality". IEEE Std. 1159 - 1995, "Recommended.

Google Scholar

[9] F.A.L. Jowder, Design and analysis of dynamic voltage restorer for deep voltage sag and harmonic compensation, Published in IET Generation, Transmission & Distribution , doi: 10. 1049/iet-gtd. 2008. 0531.

DOI: 10.1049/iet-gtd.2008.0531

Google Scholar