X-Lam Panels in Swimming-Pool Building – Monitoring the Environment and the Performance

Article Preview

Abstract:

The cross-laminated timber panels (X-Lam panels) are produced for structural use in Service Classes 1 and 2 conditions, in accordance with what is established on Eurocode 5 [. Timber boards are glued together on orthogonal layers, allowing the panel to perform two important characteristics: good dimensional stability and loading in two-way directions. The influence of wood moisture content on the feasibility of cross-laminated timber is described in this paper regarding the dimensional stability of the panels when applied in high moisture locations. Several European Technical Approvals, state the low importance of the dimensional variations with moisture content of this type of panel, but some reference values can be found in other technical documents. The French Avis Technique [[[1 reference the value of 0.01mm/m for in-plane deformation (per percentage of timber moisture variation) and the TRADA Wood Information Sheet, WIS 2/3-62 [1, refers the maximum value of 0.02mm/m for the same conditions.The use of the X-Lam panels in Service Class 3 can not be used, concerning the high level of stressing in glue lines, and no producer has yet certified it for this Service Class. Moreover, the French Avis Technique doesnt allow the use of X-Lam panels in swimming-pools due to high hygrometry, even for conditions corresponding to Service Class 2.Cross laminated timber panels are widely used across Europe but are giving the first steps in Portugal at the moment. The first big project was finished in spring 2012 in Almada, comprising a building integrating a 25 meter in-door swimming-pool and a gym. In order to assess the behavior of the timber structure, due to the non-conventional using of the X-Lam panels, a monitoring program was started immediately after building construction. The results obtained are presented and discussed in this paper.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

779-785

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Ceccotti, A. New Technologies for Construction of Medium-Rise Buildings in Seismic Regions: The Xlam Case, Structural Engineering International, 2/2008, IABSE, (2008) pp.156-165.

DOI: 10.2749/101686608784218680

Google Scholar

[2] CEN, EN 13017-1 – Solid wood panels. Classification by surface appearance. Part 1: Softwood. (2000).

Google Scholar

[3] CEN, EN 14081-1 – Timber structures. Strength graded structural timber with rectangular cross section. Part 1: Requirements. (2011).

DOI: 10.3403/30288843

Google Scholar

[4] CEN, EN 335-1 – Durability of wood and wood- based products. Definition of use classes. (2006).

Google Scholar

[5] CEN, EN 350-2 – Durability of wood and wood-based products. Natural durability of solid wood. Part 2: Guide to natural durability and treatability of selected wood species of importance in Europe. (1994).

DOI: 10.3403/00340120u

Google Scholar

[6] CEN, EN1995-1-1 – Eurocode 5: Design of Timber Structures. Part 1-1: General - Common rules and rules for buildings. (2006).

DOI: 10.3403/03174906

Google Scholar

[7] CEN, prEN 16351 Timber structures - Cross laminated timber – Requirements. CEN/TC 124 - Timber structures. (2011).

DOI: 10.3403/30253103u

Google Scholar

[8] CSTB, Avis Technique 3/06-477, Panneaux bois à usage structural – Panneaux KLH. (2011).

Google Scholar

[9] CSTB, Document Technique d'Application (Avis Technique 3/11-704), Panneaux bois à usage structural – BBS. (2012).

Google Scholar

[10] CSTB, Document Technique d'Application (Avis Technique 3/12-724), Panneaux bois à usage structural – Panneaux LENO. (2013).

Google Scholar

[11] FPL, Wood Handbook – Wood as an Engineering Material. USDA Forest Service. 1999. 463p.

Google Scholar

[12] Gülzow A., Richter K., Steiger R., Influence of wood moisture content on bending and shear stiffness of cross laminated timber panels, J. Wood Prod. (2011) 69: 193–197.

DOI: 10.1007/s00107-010-0416-z

Google Scholar

[13] Information on http: /www. klh. at.

Google Scholar

[14] LNEC, Timber for Construction: Moisture in timber – Sheet M9, 1997. (in Portuguese).

Google Scholar

[15] OIB, European Technical Approval ETA 06/0138 – KLH solid wood slabs. (2011).

Google Scholar

[16] Schickhofer, G., CLT – European Experiences, Cross-Laminated Timber Symposium. Vancouver Convention Center. Canada. (2011).

Google Scholar

[17] Teibinger, M. Urban Timber Houses in Vienna, Structural Engineering International, 2/2008, IABSE, (2008) pp.114-117.

DOI: 10.2749/101686608784218644

Google Scholar

[18] TRADA, Introduction to Specifiers, WIS 2/6-61. Wood Information Sheet. (2009).

Google Scholar