Abstract:

While measurement accuracy can be increased through continuously improving instrument precision, certain measurement errors can be eliminated via data processing using properly devised processing algorithms. Multi-point roundness error separation methods that are the subjects of study in this paper are reviewed, in particularly, three-point method and other multi-point methods that are based on three-point roundness error separation method, such as two-point method, mixed method and four-point method are summarized. Finally a comparison between each separation methods mentioned in this paper is made. Our views of future development trend in multi-point roundness error separation methods are presented.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

555-560

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Gao Linxiang and Xie Huichong: Journal of Northwestern Polytechnical University Vol. 6, No. 1 (1988), pp.1-6.

Google Scholar

[2] Ye Jingsheng: Acta Metrologic Sinica Vol. 13, No. 3 (1992), pp.170-175.

Google Scholar

[3] Aoh Yasuo, et al.: Precision Machinery Vol. 32, No. 12 (1966), pp.831-836.

Google Scholar

[4] Wei Gao, Satoshi Kiyono and Tadatoshi Nomura: Precision Engineering Vol. 19, No. 1 (1996), pp.37-45.

Google Scholar

[5] Wei Gao, Satoshi Kiyono and Takamitu Sugawara: Precision Engineering Vol. 21(1997), pp.123-133.

Google Scholar

[6] Hong Maisheng et al.: Journal of Vibration, Measurement & Diagnosis Z1(1983), pp.1-10.

Google Scholar

[7] Hong Maisheng et al.: China Mechanical Engineering Vol. 8, No. 2 (1997), pp.88-92.

Google Scholar

[8] Hong Maisheng, Wei Yuanlei and Li Jishun: China Mechanical Engineering Vol. 3(2000), pp.245-248.

Google Scholar

[9] Hong Maisheng, Deng Zhonghuang and Cheng Jianqiang: Journal of Shanghai Jiaotong University Vol. 34, No. 10 (2000), pp.1318-1319.

Google Scholar

[10] Hong Maisheng, et al.: Chinese Journal of Scientific Instrumentation Vol. 24, No. 2 (2003), pp.152-156.

Google Scholar

[11] G.X. Zhang, et al.: Annals of the CIRP Vol. 42, No. 1 (1993), pp.593-596.

Google Scholar

[12] Eric R. Marsha, et al.: Precision Engineering Vol. 34 (2010), pp.85-91.

Google Scholar

[13] Zhang Bangcheng, et al.: Detecting instrument. (2005), pp.75-77.

Google Scholar