Defects Analysis and Reconstruction for 10kV Circuit Breaker

Article Preview

Abstract:

The defect types of 10kV VS1 circuit breaker were surveyed in order to reduce the defective ratio. Then, the main reason of these defects was found that the opening time of circuit breaker was too long. The reasons that cause circuit breaker opening time exceed were studied, and the effective reconstruction measures were developed though test verification and analysis. To compare with the statistics before reconstruction, the result shows that the reconstruction methods using in this paper were simple and easy to perform, which can reduce the opening time of circuit breaker, improve the reliability of the devices, and play a positive role in the security and stabilization of power system. It provides a basis for improving the efficiency of characteristics test at other voltage levels.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 805-806)

Pages:

930-934

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] LIU Zhaolin, YANG Linghui, GAO Kai. Application of defects analysis and life estimation for 500kV circuit breakers to LCM [J]. East china electric power, 2009, 37(12): 2044-2046 (In Chinese).

Google Scholar

[2] Huang Liang, Ye Liqun, Guo Jiemin. State evaluation diagnosis and its maintenance for 10kV vacuum circuit breaker [J]. Guangdong technology, 2011, 1(5): 118-121. (In Chinese).

Google Scholar

[3] Li Dapeng. Fault and treatment of vacuum circuit breaker [J]. Electro technical Application, 2009, 28(22): 52-53, 64. (In Chinese).

Google Scholar

[4] Xu Huan. Structure introduction and fault treatment of VS1vacuum circuit breaker[C]. The 14th low voltage apparatus subcommittee academic annual meeting, China Electrical Technology Association, 2008. pp.103-104. (In Chinese).

Google Scholar

[5] An Tao. VS1 Circuit Breaker (CB) on-line monitoring and fault diagnosis system [D]. Zhejiang University, 2010. (In Chinese).

Google Scholar

[6] Mao Yiyuan. Cooperation between operating mechanism and 10kV vacuum circuit breaker in fixed cabinet [J]. High Voltage Apparatus, 1999, 56(5): 56-57. (In Chinese).

Google Scholar

[7] Dong Xiaotao. Defects analysis and reconstruction for LW12-500 circuit breaker [J]. High Voltage Engineering, 2006, 32(4): 119-121. (In Chinese).

Google Scholar