Preparation of Copper Doped L-Threonine Modified Electrode and its Application in Determination of Hydroquinone

Article Preview

Abstract:

A copper doped L-threonine modified electrode was prepared by cyclic voltammetry (CV), and the electrochemical behavior of hydroquinone at the modified electrode had been studied. A novel determination method of hydroquinone using CV, chronoamperometry and differential pulse voltammetry (DPV) was established, and the scan rate and supporting electrolyte factors on catalytic oxidation of hydroquinone in modified electrodes were discussed. The results revealed that the modified electrode had showed obvious electrocatalytic activity for hydroquinone, and anodic peak current increased linearly with the concentration of hydroquinone in the range of 0.8-150 μmol/L with the detection limit of 0.4 μmol/L (S/N=3). The method has been applied to the determination of hydroquinone in water sample with satisfactory results.the recovery ranged from 95.9 % to 105.2 %.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

413-418

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] S.M. Yang, Z.P. Wei, G.H. Hu, Simultaneous determination of catechol and hydroquinone at a carbon nanotubes Modified electrode, Chem. J. Chinese Universities. 31(2010) 264-268.

Google Scholar

[2] Y. P. Ding, W. L. Liu, Q. S. Wu, Direct simultaneous determination of dihydroxybenzene isomers at C-nanotube- modified electrodes by derivativevoltammetry, J . Electroanal Chem. 575(2005): 275-280.

DOI: 10.1016/j.jelechem.2004.09.020

Google Scholar

[3] B.G. T Corominas, M. Catalá Icardo, L. L. Zamora, A tandem-flow assembly for the chemiluminometric determination of hydroquinone, Talanta, 64(2004) 618-625.

DOI: 10.1016/j.talanta.2004.03.031

Google Scholar

[4] L.F. Yao, H.B. He, Y.Q. Feng, HPLC separation of positional isomers on a dodecylamine-N, N-dimethyleneph- osphonic acid modified zirconia stationary phase, Talanta. 64 ( 2004) 244-251.

DOI: 10.1016/j.talanta.2004.02.019

Google Scholar

[5] S.P. Huang, J.R. Xu, Q. Wang, Simultaneous determination of o-, m-, p-dihydroxybenzene isomer by thin-layer chromatography, Chinese J. Anal. Chem. 27(1999): 331-33.

Google Scholar

[6] B. Pranaityte, A. Padarauskas, Micellar electrokinetic chromatography at low pH with polyelectrolyte-coated capillaries, J. Chromatogr.A. 1042(2004): 197-202.

DOI: 10.1016/j.chroma.2004.05.036

Google Scholar

[7] Y.P. Ding, W. L. Liu, Q.S. Wu, Direct simultaneous determination of dihydroxybenzene isomers at C-nanotube- modified electrodes by derivativevoltammetry, J. Electroanal Chem. 575(2005) 275-280.

DOI: 10.1016/j.jelechem.2004.09.020

Google Scholar

[8] W. Ma, D. M. Sun, The electrochemical properties of dopamine, epinephrine and their simultaneous determination at a poly( L-methionine) modified electrode, Russ. J. Electrochem. 43 (2007) 1382-1389.

DOI: 10.1134/s1023193507120087

Google Scholar

[9] W. N. Hu, D. M. Sun, W. Ma, Silver Doped poly (L-valine) modified glassy carbon electrode for the simultaneous determination of uric acid, ascorbic acid and dopamine, Electroanalysis. 22(2010) 584-589.

DOI: 10.1002/elan.200900376

Google Scholar