Comparison of HPLC and Spectrophotometry Methods on Quantitative Determination of Formaldehyde in Water Based Coatings

Article Preview

Abstract:

To explore and compare the reliability of the quantitative determination of formaldehyde content of water based coatings, the high performance liquid chromatography (HPLC) after derivatization to 2.4-dinitrophenylhydazone and UV-VIS spectrophotometry were studied, respectively. HPLC was performed on a C18 column with acetonitrile/water (65/35, V/V) as mobile phase at a flow rate of 1.0 mL/min, and analyses was detected using Photodode Array Detector (DAD) at the wavelength of 360 nm. And formaldehyde was determined with spectrophotometry at 435nm. The result showed the standard curve of formaldehyde by the HPLC method was linear in the range of 0.1-5.0 mg/L (R2=0.9998). The detection limit was 0.96mg/kg, recoveries were ranging from 96.2% to 101.3%. The linear range of formaldehyde by the spectrophotometric method was 0.1~5.0 mg/L (R2=0.9995), and the detection limit was 5.93mg/kg, recoveries were ranging from 98.5% to 105.3%. In conclusion, both the two methods can be used for quantitative analysis of formaldehyde in water based coatings, and the major advantages of HPLC are quick, simple and sensitive.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 816-817)

Pages:

433-438

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] O. Bunkoed, F. Davis, P. Kanatharana, and P. Thavarungkul: Sol–gel based sensor for selective formaldehyde determination, Anal. Chim. Acta 659(2010) 251–257.

DOI: 10.1016/j.aca.2009.11.034

Google Scholar

[2] X.F. Wang, B. Ding and M. Sun: Nanofibrous polyethyleneimine membranes as sensitive coatings for quartz crystal microbalance-based formaldehyde sensors, Sens. Actuators B 144 (2010) 11–17.

DOI: 10.1016/j.snb.2009.08.023

Google Scholar

[3] C.H. Chou, J.L. Chang and J.M. Zen: Effective analysis of gaseous formaldehyde based on a platinum-deposited screen-printed edge band ultramicroelectrode coated with Nafion as solid polymer electrolyte, Sens. Actuators B 147 (2010) 669–675.

DOI: 10.1016/j.snb.2010.03.090

Google Scholar

[4] Baez, A., et al., 2003. Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa, Mexico. The Science of the Total Environment 302, 211–226.

DOI: 10.1016/s0048-9697(02)00344-3

Google Scholar

[5] S. Barguil , Le Moullec, Y., and Person, A.: Chemical characterisation of indoor air quality in Parisian homes. Aerobiologia 6(1990), 28–31.

DOI: 10.1007/bf02539038

Google Scholar

[6] De Bortoli, M.: Concentrations of selected organic pollutants in indoor and outdor air in Northern Italy. Environment International 12(1986), 343–350.

DOI: 10.1016/0160-4120(86)90048-6

Google Scholar

[7] J. Jurvelin, M. Vartiainen, and M. Jantunen: Personal exposure levels and microenvironmental concentrations of formaldehyde and acetaldehyde in the Helsinki Metropolitan Area, Finland. Journal of Air Waste Management Associa-tion 51(2001), 17–24.

DOI: 10.1080/10473289.2001.10464251

Google Scholar

[8] C. Marchand, B. Bulliot and S. Le Calve: Aldehyde measurements in indoor environment in Strasbourg (France). Atmospheric Environment 40(2006), 1336–1345.

DOI: 10.1016/j.atmosenv.2005.10.027

Google Scholar

[9] P. Hu, N. Han, X. Zhang and M.S. Yao: Fabrication of ZnO nanorod-assembled multishelled hollow spheres and enhanced performance in gas sensor, J. Mater. Chem. 21 (2011) 14277–14284.

DOI: 10.1039/c1jm11919b

Google Scholar

[10] Y.J. Lu, M. Meyyappan, J. Li: A carbon-nanotube-based sensor array for formaldehyde detection, Nanotechnology 22 (2011) 055502.

DOI: 10.1088/0957-4484/22/5/055502

Google Scholar

[11] Z.J. Wang, J. Liu and F.J. Wang: Size-controlled synthesis of ZnSnO(3) cubic crystallites at low temperatures and their HCHO-sensing properties, J. Phys. Chem. C 114 (2010) 13577–13582.

DOI: 10.1021/jp104733e

Google Scholar

[12] Pal, R. and Kim, K. H.: Experimental choices for the determination of carbonyl compounds in air. Journal of Separation Science, 30 (2007), 2708–2718.

DOI: 10.1002/jssc.200700206

Google Scholar

[13] K.J. Dennis, T. Shibamoto, Gas chromatographic analysis of reactive carbonyl compounds formed from lipids upon UV-irradiation, Lipids 25 (1990) 460–464.

DOI: 10.1007/bf02538089

Google Scholar

[14] Chen, J. W., Li, H. M. and Ding, F. L.: Determination of formaldehyde in soak of marine products with HPLC method. Preventive Medicine Tribune, 15(2009), 157–158.

Google Scholar

[15] Pal, R. and Kim, K. H.: Influences of sampling volume and sample concentration on the analysis of atmospheric carbonyls by 2, 4-dinitrophenylhydrazine cartridge. Analytical Chimica Acta, 610(2008), 289–296.

DOI: 10.1016/j.aca.2008.01.034

Google Scholar

[16] Saito,Y., Ueta, I., Ogawa, M. and Jinno, K.: Simultaneous derivatization preconcentration of volatile aldehydes with a miniaturized fiber-packed sample preparation device designed for gas chromatographic analysis. Analytical and Bioanalytical Chemistry, 386(2006).

DOI: 10.1007/s00216-006-0509-z

Google Scholar

[17] Schulte, E.: Determination of higher carbonyl compounds in used frying fats by HPLC of DNPH derivatives. Analytical and Bioanalytical Chemistry, 372(2002), 644–648.

DOI: 10.1007/s00216-001-1228-0

Google Scholar

[18] C. Marchand, B. Bulliot, and S. Le Calve: Aldehyde measurements in indoor environment in Strasbourg (France). Atmospheric Environment 40(2006), 1336–1345.

DOI: 10.1016/j.atmosenv.2005.10.027

Google Scholar

[19] Wenhong Luo, Hui Li and Yuan Zhang: Determination of formaldehyde in blood plasma by high-performance liquid chromatography with fluorescence detection. Journal of Chromatography B, 753(2001): 253~257.

DOI: 10.1016/s0378-4347(00)00552-1

Google Scholar

[20] Standard Method for Indoor Air Quality Measurement, GB/T 18883-2002, Chinese Standardization Administration of China, (2002).

Google Scholar