Environmental Monitoring of Acetic Acid Gas by Thin Film Polyaniline Sensor

Article Preview

Abstract:

The acetic acid gas, as a kind of organic pollutants, can cause severe damage to both people and materials, and has received much attention as a problem. In this paper, a QCM sensor coated with the polyaniline film was employed as a gas sensor to detect the content of the acetic acid gas. The polyaniline film was electrochemical polymerized in situ on the silver electrode surface of quartz crystal microbalance (QCM) sensor and employed as sensing film for detection of acetic acid gas. Responses of the QCM sensors coated with the polyaniline film to different concentrations of the acetic acid gas as a function of time was presented. And the frequency shifts of QCM showed a linear correlation of the concentration of acetic acid gas. The result of our experiment fully indicated that the QCM sensor with the polyaniline film appear to respond effectively and sensitively to the acetic acid gas within the range of experimental concentrations. Such sensor will have potential application in our living environment for real-time monitoring.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 864-867)

Pages:

913-918

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] R.K. Lav, P. Suranjan, H.L. Dong: Sensors and Actuators B: Chemical Vol. 153(1) (2011), pp.1-10.

Google Scholar

[2] M.L. Huang, M.L. Chung: Chemosphere Vol. 68(4) (2007), pp.781-789.

Google Scholar

[3] P. Brimblecombe, C.M. Grossi: Chemistry Central Journal Vol. 6(1) (2012), p.21.

Google Scholar

[4] L. Malherbe, C. Mandin: Atmospheric Environment Vol. 41(30) (2007), pp.6322-6330.

Google Scholar

[5] O. Santino: Atmospheric Environment Vol. 45(10) (2011), pp.1888-1895.

Google Scholar

[6] Z.L. Que, F.B. Wang, J.Z. Li, et al: Composites Part B: Engineering Vol. 49(1) (2013), pp.36-42.

Google Scholar

[7] C.Y. Peng, C.H. Lan, C.Y. Yang: Biomass and Bioenergy Vol. 36(1)(2012 ), pp.96-106.

Google Scholar

[8] J.Y. Zheng, Y.F. Yu, Z.W. Mo, et al: Science of The Total Environment Vol. 456-457(1) (2013), pp.127-136.

Google Scholar

[9] M. Ryhl-Svendsen, J. Glastrap: Atmospheric Environment Vol. 36(24) (2002), pp.3909-3916.

Google Scholar

[10] X.M. Xu, H.W. Cang, C.Z. Li, et al: Talanta Vol. 78(3) (2009), pp.711-716.

Google Scholar

[11] M. Harbeck, C. Tasaltin, I. Gurol, et al: Sensors and Actuators B Vol. 150(2) (2010), pp.616-624.

Google Scholar

[12] X.X. Jin, Y. Huang, A. Mason, et al: Analytical chemistry Vol. 81(2) (2009), pp.595-603.

Google Scholar

[13] B. Adhikari, S. Majumdar: Progress In Polymer Science Vol. 29(7) (2004), p.699–766.

Google Scholar

[14] J. Huang, T.L. Yang, Y.F. Kang, et al: Journal of Natural Gas Chemistry Vol. 20(5) (2011), pp.515-519.

Google Scholar

[15] Z.F. Du, C.C. Li, L.M. Li: Journal of Materials Science-materials in Electronics Vol. 22(4) (2011), pp.418-421.

Google Scholar

[16] S. Srivastava, S.S. Sharma, S. Kumar: International Journal of Hydrogen Energy Vol. 34(19) (2009), pp.8444-8450.

Google Scholar

[17] D. Nicolas-Debarnot, F. Poncin-Epaillard: Analytica Chimica Acta Vol. 475(1-2) (2003), p.1–15.

DOI: 10.1016/s0003-2670(02)01229-1

Google Scholar

[18] X.X. Li, M. Ju, X.W. Li: Sensors and Actuators B Vol. 97(2004), p.144–147.

Google Scholar

[19] A.A. Khan, U. Baig, M. Khalid: Journal of Hazardous Materials Vol. 186 (2-3) (2011), p.2037-(2042).

Google Scholar

[20] H.Q. Fang, G.X. Li, H.Y. Chen: Chemical Journal of Chinese Universities Vol. 15(3) (1994), pp.348-351.

Google Scholar