Research of Primary Frequency Regulation Control Strategy Based on Stimulative Simulation System

Article Preview

Abstract:

The once-through boiler is widely used in high capacity unit currently, however its heat storage capacity is small, and the unit’s response lags during primary frequency regulation. These all lead to the limited frequency regulation ability. For the purpose of studying the primary frequency regulation optimized control strategy, this paper established a primary frequency regulation characteristic simulation platform based on stimulative simulation system. Using this platform, it proposed an improved program for once-through boiler’s primary frequency regulation control strategy. It’s supposed to cover the insufficient heat storage capacity of the boiler by introducing the differential feed forward signal of the fuel supply and water flow. The simulation result shows that the proposed control scheme effectively improves the speed of primary frequency regulation. This platform provides a reliable basis for once-through boiler’s primary frequency regulation control strategy, and also has a certain guiding significance for further study.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

491-497

Citation:

Online since:

May 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Song Junying, Zhou Yong, Huang Lianggang, etc. The research of primary frequency control's input of Hunan power grid generating set [J]. Hunan Electric Power. 2006, 26(4): 1-3.

Google Scholar

[2] Wang Jiasheng, Deng Tongtian, Ran Jingchuan. The research of Thermal power units' start-up and operation mode in Solitary (small) grid. [J]. Automation of electric Power Systems, 2008, 32(21): 102-106.

Google Scholar

[3] Li Duan Chao, Chen Shi, Chen Zhongyuan. The efficiency of the real-time measurement and compensation method of generator sets' primary frequency control [J], Automation of electric Power Systems, 2004, 28(2): 70-72.

Google Scholar

[4] Li Miao. Research on Some Problems of Generation-network's Optimized Coordination in Power System [D]. Wuhan: Wuhan University, 2012. 5.

Google Scholar

[5] Gao Xiang, etc. Modern power grid frequency control [M]. Beijing: China Electric Power Press, 2010. 9.

Google Scholar

[6] Jin Na, Liu Wenying, Cao Yinli, etc. The influence of high-capacity unit's primary frequency control parameters to power grid frequency characteristic [J], Power System Protection and Control, 2012, 40(1): 91-100.

Google Scholar

[7] Liu Le. Research on Frequency Bias Coefficient in Automatic Generation Control [D], Dalian: Dalian University of Technology, 2008. 5.

Google Scholar

[8] Han Pu, Wang Wenzhi, Zhai Yongjie, etc. The design and development of virtual DCS-based hybrid simulation system [J]. Journal of North China Electric Power University, 2010, 25(4): 101-106.

Google Scholar

[9] Ma Junchi, Shen Zhongli, Niu Yuguang, etc. Simulative simulation system of the 1000MW ultra supercritical unit [J], Journal of Electric Power Science and Technology, 2010, 25(4): 101-106.

Google Scholar