Voltage Dip/Swell Mitigation and Imaginary Power Compensation in Low Voltage Distribution Utilizing Improved Unified Power Quality Conditioner (I-UPQC)

Article Preview

Abstract:

The main purpose of this work is to introduced power quality improvement in low voltage distribution networks with the application of Improved Unified Power Quality Conditioner (I-UPQC). Ordinarily, in the normal UPQC, the series inverter handles active injection while the shunt inverter provides load imaginary power injection. However, in the case of I-UPQC, the series inverter of the UPQC performs two functions concurrently as a sag and swell compensator and assists the shunt inverter in load reactive power requirements. The reactive power sharing is achieved by the integration of the Power Angle Control (PAC) of UPQC to coordinate imaginary power-sharing between the two inverters. With the view that the series inverter produces active and reactive power, this concept is named I-UPQC. Full mathematical analysis to extend the PAC method to I-UPQC has been carried out in this work. The simulation and results produced in the MATLAB / SIMULINK environment and discussion to support the developed concept are also presented. The result from the proposed concept is confirmed by comparing the concept with operation unified power quality conditioner in steady-state.

You might also be interested in these eBooks

Info:

Pages:

84-103

Citation:

Online since:

June 2020

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2020 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] S. K. Dash and P. K. Ray, Power quality improvement utilizing PV fed unified power quality conditioner based on UV-PI and PR-R controller,, CPSS Transactions on Power Electronics and Applications, vol. 3, pp.243-253, (2018).

DOI: 10.24295/cpsstpea.2018.00024

Google Scholar

[2] Q. Xu, F. Ma, A. Luo, Z. He, and H. Xiao, Analysis and control of M3C-based UPQC for power quality improvement in medium/high-voltage power grid,, IEEE Transactions on Power Electronics, vol. 31, pp.8182-8194, (2016).

DOI: 10.1109/tpel.2016.2520586

Google Scholar

[3] X. Yunfei, X. Xiangning, S. Yamin, and L. Yunbo, Voltage sag compensation strategy for unified power quality conditioner with simultaneous reactive power injection,, Journal of Modern Power Systems and Clean Energy, vol. 4, pp.113-122, (2016).

DOI: 10.1007/s40565-016-0183-x

Google Scholar

[4] L. An, X. Qianming, M. Fujun, and C. Yandong, Overview of power quality analysis and control technology for the smart grid,, Journal of Modern Power Systems and Clean Energy, vol. 4, pp.1-9, (2016).

Google Scholar

[5] R. C. Dugan, M. F. McGranaghan, H. W. Beaty, and S. Santoso, Electrical power systems quality,, (1996).

Google Scholar

[6] C. R. Bayliss and B. J. Hardy, Chapter 25 - Power Quality – Voltage Disturbances,, in Transmission and Distribution Electrical Engineering (Fourth Edition), C. R. Bayliss and B. J. Hardy, Eds., ed Oxford: Newnes, 2012, pp.1013-1026.

DOI: 10.1016/b978-0-08-096912-1.00025-3

Google Scholar

[7] M. El-Habrouk, M. Darwish, and P. Mehta, Active power filters: A review,, IEE Proceedings-Electric Power Applications, vol. 147, pp.403-413, (2000).

DOI: 10.1049/ip-epa:20000522

Google Scholar

[8] N. G. Hingorani, L. Gyugyi, and M. El-Hawary, Understanding FACTS: concepts and technology of flexible AC transmission systems vol. 1: IEEE press New York, (2000).

Google Scholar

[9] A. Kapoor and R. Mahanty, A quasi passive filter for power quality improvement,, in Proceedings of IEEE International Conference on Industrial Technology 2000 (IEEE Cat. No. 00TH8482), 2000, pp.526-529.

DOI: 10.1109/icit.2000.854215

Google Scholar

[10] B. Singh, K. Al-Haddad, and A. Chandra, A review of active filters for power quality improvement,, IEEE transactions on industrial electronics, vol. 46, pp.960-971, (1999).

DOI: 10.1109/41.793345

Google Scholar

[11] J. Wen, L. Zhou, and K. Smedley, Power quality improvement at medium-voltage grids using hexagram active power filter,, in 2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC), 2010, pp.47-57.

DOI: 10.1109/apec.2010.5433696

Google Scholar

[12] H. Akagi, New trends in active filters for improving power quality,, in Proceedings of International Conference on Power Electronics, Drives and Energy Systems for Industrial Growth, 1996, pp.417-425 vol.1.

DOI: 10.1109/pedes.1996.539652

Google Scholar

[13] A. Chaoui, J.-P. Gaubert, and F. Krim, Power quality improvement using DPC controlled three-phase shunt active filter,, Electric Power Systems Research, vol. 80, pp.657-666, (2010).

DOI: 10.1016/j.epsr.2009.10.020

Google Scholar

[14] R. Zahira and A. P. Fathima, A technical survey on control strategies of active filter for harmonic suppression,, Procedia Engineering, vol. 30, pp.686-693, (2012).

DOI: 10.1016/j.proeng.2012.01.915

Google Scholar

[15] J. Turunen and H. Tuusa, Improvement of the voltage compensation performance of the series active power filter using a simple PI-control method,, in 2007 European Conference on Power Electronics and Applications, 2007, pp.1-9.

DOI: 10.1109/epe.2007.4417718

Google Scholar

[16] N. Mesbahi, A. Ouari, D. O. Abdeslam, T. Djamah, and A. Omeiri, Direct power control of shunt active filter using high selectivity filter (HSF) under distorted or unbalanced conditions,, Electric Power Systems Research, vol. 108, pp.113-123, (2014).

DOI: 10.1016/j.epsr.2013.11.006

Google Scholar

[17] R. A. Hooshmand and M. T. Esfahani, A new combined method in active filter design for power quality improvement in power systems,, ISA transactions, vol. 50, pp.150-158, (2011).

DOI: 10.1016/j.isatra.2010.12.001

Google Scholar

[18] H.-L. Jou, J.-C. Wu, K.-D. Wu, M.-S. Huang, and C.-A. Lin, A hybrid compensation system comprising hybrid power filter and AC power capacitor,, International Journal of Electrical Power & Energy Systems, vol. 28, pp.448-458, 2006/09/01/ (2006).

DOI: 10.1016/j.ijepes.2006.02.008

Google Scholar

[19] R. Khanna, S. T. Chacko, and N. Goel, Performance and investigation of hybrid filters for Power Quality Improvement,, in 2011 5th International Power Engineering and Optimization Conference, 2011, pp.93-97.

DOI: 10.1109/peoco.2011.5970409

Google Scholar

[20] O. O. Osaloni and A. K. Saha, Distributed Generation Interconnection with Improved Unified Power Quality Conditioner for Power Quality Mitigation,, in 2020 International SAUPEC/RobMech/PRASA Conference, 2020, pp.1-6.

DOI: 10.1109/saupec/robmech/prasa48453.2020.9041125

Google Scholar

[21] G. T. R. Das, A review of UPQC topologies for reduced DC link voltage with MATLAB simulation models,, in 2016 international conference on emerging trends in engineering, technology and science (ICETETS), 2016, pp.1-7.

DOI: 10.1109/icetets.2016.7603075

Google Scholar

[22] K. S. Reddy, A. Bhaktavastala, and V. R. Reddy, UPQC-S: a novel concept of simultaneous voltage sag and swell and load reactive power compensations utilizing series inverter of UPQC,, Int. J. of Eng. and Adv. Tech.(IJEAT), vol. 3, pp.174-180, (2013).

DOI: 10.1109/tpel.2011.2106222

Google Scholar

[23] V. Khadkikar and A. Chandra, UPQC-S: A novel concept of simultaneous voltage sag and swell and load reactive power compensations utilizing series inverter of UPQC,, IEEE Transactions on Power Electronics, vol. 26, pp.2414-2425, (2011).

DOI: 10.1109/tpel.2011.2106222

Google Scholar

[24] G. S. Kumar, P. H. Vardhana, B. K. Kumar, and M. K. Mishra, Minimization of VA loading of unified power quality conditioner (UPQC),, in 2009 International Conference on Power Engineering, Energy and Electrical Drives, 2009, pp.552-557.

DOI: 10.1109/powereng.2009.4915152

Google Scholar

[25] V. Khadkikar, Enhancing Electric Power Quality Using UPQC: A Comprehensive Overview,, IEEE Transactions on Power Electronics, vol. 27, pp.2284-2297, (2012).

DOI: 10.1109/tpel.2011.2172001

Google Scholar

[26] Y. Bouzelata, E. Kurt, R. Chenni, and N. Altın, Design and simulation of a unified power quality conditioner fed by solar energy,, International Journal of Hydrogen Energy, vol. 40, pp.15267-15277, 2015/11/26/ (2015).

DOI: 10.1016/j.ijhydene.2015.02.077

Google Scholar

[27] L. Zhou, Q. Fu, and C. Liu, Modeling and Control Analysis of a Hybrid Unified Power Quality Conditioner,, in 2009 Asia-Pacific Power and Energy Engineering Conference, 2009, pp.1-5.

DOI: 10.1109/appeec.2009.4918490

Google Scholar

[28] I. Axente, J. N. Ganesh, M. Basu, M. F. Conlon, and K. Gaughan, A 12-kVA DSP-controlled laboratory prototype UPQC capable of mitigating unbalance in source voltage and load current,, IEEE Transactions on power Electronics, vol. 25, pp.1471-1479, (2010).

DOI: 10.1109/tpel.2010.2040635

Google Scholar

[29] M. Basu, S. Das, and G. K. Dubey, Investigation on the performance of UPQC-Q for voltage sag mitigation and power quality improvement at a critical load point,, IET generation, transmission & distribution, vol. 2, pp.414-423, (2008).

DOI: 10.1049/iet-gtd:20060317

Google Scholar

[30] V. Khadkikar and A. Chandra, A novel control approach for unified power quality conditioner Q without active power injection for voltage sag compensation,, in 2006 IEEE International Conference on Industrial Technology, 2006, pp.779-784.

DOI: 10.1109/icit.2006.372356

Google Scholar

[31] M.-S. Yun, W.-C. Lee, I. Suh, and D.-S. Hyun, A new control scheme of unified power quality compensator-Q with minimum power injection,, in 30th Annual Conference of IEEE Industrial Electronics Society, 2004. IECON 2004, 2004, pp.51-56.

DOI: 10.1109/iecon.2004.1433283

Google Scholar

[32] Y. Y. Kolhatkar and S. P. Das, Experimental investigation of a single-phase UPQC with minimum VA loading,, IEEE Transactions on Power Delivery, vol. 22, pp.373-380, (2006).

DOI: 10.1109/tpwrd.2006.881471

Google Scholar

[33] D. O. Kisck, V. Navrapescu, and M. Kisck, Single-phase unified power quality conditioner with optimum voltage angle injection for minimum VA requirement,, in 2007 IEEE International Symposium on Industrial Electronics, 2007, pp.2443-2448.

DOI: 10.1109/isie.2007.4374990

Google Scholar

[34] L. Gyugyi, Unified power-flow control concept for flexible AC transmission systems,, in IEE proceedings C (generation, transmission and distribution), 1992, pp.323-331.

DOI: 10.1049/ip-c.1992.0048

Google Scholar

[35] V. Khadkikar, A. Chandra, A. Barry, and T. Nguyen, Analysis of power flow in UPQC during voltage sag and swell conditions for selection of device ratings,, in 2006 Canadian Conference on Electrical and Computer Engineering, 2006, pp.867-872.

DOI: 10.1109/ccece.2006.277324

Google Scholar

[36] V. Khadkikar and A. Chandra, A new control philosophy for a unified power quality conditioner (UPQC) to coordinate load-reactive power demand between shunt and series inverters,, IEEE transactions on power delivery, vol. 23, pp.2522-2534, (2008).

DOI: 10.1109/tpwrd.2008.921146

Google Scholar

[37] C. Kamal, P. Aditya, K. Sujes, and M. K. Jainuddin, A Novel Approach For UPQC of Improve The Power Quality.,.

Google Scholar