Mitigation of Reactive Power and Harmonics in a Case of Industrial Customer

Article Preview

Abstract:

In most industrial plants, power quality is a major issue which hinders productivity and efficiency of the plants due to the use of semiconductor based loads and non-linear loads. As a result, to address the power quality problems in these industries, specialized power devices such as the Unified Power Quality Conditioner (UPQC), can be installed at the customer's location to resolve practically all power quality issues. UPQC consist of a series of active power filters (APF) which mitigate voltage quality issues and shunt active power filters which are used to reduce current quality issues, like harmonics and reactive power burdens. This paper, therefore presents an investigation and assessment of the power quality problems associated with Bahir Dar Textile Share Company. This was achieved by examining the voltage and current harmonic levels of various types of loads using PI and fuzzy logic controllers by measuring the level of total harmonic distortion (THD) with and without the insertion of the UPQC. The novelty of this paper is the implementation of the controller based customized UPQC for power factor and reactive power compensation. It was observed that by designing the system without and with UPQC, the results of the FFT analysis show that the fuzzy logic controller (FLC) reduced the harmonics level of the load voltage and current by 1.10% and 2.14% respectively. Generally, harmonics was alleviated by 90%, reactive power was reduced by 20%, and power factor was improved by 33%. Hence, the proposed UPQC is capable of holding the voltage and current harmonics levels within the acceptable limit, which satisfies the standards imposed by IEEE 519-1995.

You might also be interested in these eBooks

Info:

Pages:

107-124

Citation:

Online since:

May 2022

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2022 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] B. Adineh, R. Keypour, P. Davari, and F. Blaabjerg, Review of harmonic mitigation methods in microgrid: From a hierarchical control perspective, IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 9, no. 3, pp.3044-3060, (2020).

DOI: 10.1109/jestpe.2020.3001971

Google Scholar

[2] H. Fujita, and H. Akagi, The unified power quality conditioner: the integration of series-and shunt-active filters, IEEE Transactions on Power Electronics, 13(2) (1998) 315-322.

DOI: 10.1109/63.662847

Google Scholar

[3] C.U. Eya, A.O. Salau, and S.E. Oti, Constant and wireless controlled DC-to-AC based boost differential converter with a sensor-less changeover system. Int J Syst Assur Eng Manag (2021).

DOI: 10.1007/s13198-021-01451-x

Google Scholar

[4] C.U. Eya, A.O. Salau, and S.E. Oti, High performance dc-to-ac converter using snubberless hbridge power switches and an improved dc-to-dc converter, International Journal of Circuits, Systems and Signal Processing, 15 (2021) 315-333.

DOI: 10.46300/9106.2021.15.36

Google Scholar

[5] D. Kumar, and V. R. Kota, Fuzzy-PI Controller based Modulated Multilevel UPQC under Faulty Conditions, Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering), 13(7) (2020) 1010-1021.

DOI: 10.2174/2352096513666200121094609

Google Scholar

[6] K. Swetha and V. Sivachidambaranathan, Reactive power control and harmonic mitigation by using DSTATCOM with different controllers, 3rd International conference on Electronics, Communication and Aerospace Technology (ICECA), Coimbatore, India (2019) 490-496.

DOI: 10.1109/iceca.2019.8822160

Google Scholar

[7] D. B. Aeggegn, A. O. Salau, and Y. Gebru, Load flow and contingency analysis for transmission line outage, Archives of Electrical Engineering, 69(3), (2020) 581-594.

Google Scholar

[8] O.P. Mahela, A.G. Shaik, Power quality improvement in distribution network using DSTATCOM with battery energy storage system, Int. J. Electr. Power Energy Syst. 2016, 83, 229–240.

DOI: 10.1016/j.ijepes.2016.04.011

Google Scholar

[9] M. Addisu, A.O. Salau, H. Takele, Fuzzy Logic Based Optimal Placement of Voltage Regulators and Capacitors for Distribution Systems Efficiency Improvement, Heliyon, 7(8) (2021), e07848.

DOI: 10.1016/j.heliyon.2021.e07848

Google Scholar

[10] V. Dovgun, S. Temerbaev, M. Chernyshov, V. Novikov, N. Boyarskaya, E. Gracheva, Distributed Power Quality Conditioning System for Three-Phase Four-Wire Low Voltage Networks, Energies 13 (2020), 4915.

DOI: 10.3390/en13184915

Google Scholar

[11] M.A. Mulla, R. Chudamani, A. Chowdhury, A novel control method for series hybrid active power filter working under unbalanced supply conditions, Int. J. Electr. Power Energy Syst. 64 (2015) 328–339.

DOI: 10.1016/j.ijepes.2014.07.022

Google Scholar

[12] A. Patel, H.D. Mathur, S. Bhanot, An improved control method for unified power quality conditioner with unbalanced load, Int. J. Electr. Power Energy Syst. 100 (2018) 129–138.

DOI: 10.1016/j.ijepes.2018.02.035

Google Scholar

[13] Y. Hoon, M.A.M. Radzi, M.K. Hassan, N.F. Mailah, Control algorithms of shunt active power filter for harmonics mitigation: A review, Energies 10 (2017) (2038).

DOI: 10.3390/en10122038

Google Scholar

[14] P. Kumara and V. Gupta, Power quality improvements using fuzzy logic based UPQC, International Journal of Latest Trends in Engineering Technology 6(4) (2016) 6-12.

DOI: 10.21172/164.002

Google Scholar

[15] K. S. Sambaiah and T. Jayabarathi, Loss minimization techniques for optimal operation and planning of distribution systems: A review of different methodologies, International Transactions on Electrical Energy Systems (2019).

DOI: 10.1002/2050-7038.12230

Google Scholar

[16] F. Mebrahtu, A. O. Salau, T. F. Agajie, and B. Khan, Harmonics mitigation using space vector pulse width modulation and shunt active power filter, International Journal on Electrical Engineering and Informatics, 12(2) (2020) 98-415.

Google Scholar

[17] F. Roos and R.C. Bansal, Reactive power and harmonic compensation: A case study for the coal-mining industry, J. energy South. Afr. 30(1) (2019) 34-48.

DOI: 10.17159/2413-3051/2019/v30i1a2473

Google Scholar

[18] I. A. Adejumobi, O. I. Adebisi and J. E. Amatu, Harmonics Mitigation on Industrial Loads Using Series and Parallel Resonant Filters, Nigerian Journal of Technology (NIJOTECH) 36(2) (2017) 611-620.

DOI: 10.4314/njt.v36i2.37

Google Scholar

[19] P. T. Ogunboyo, R. Tiako, and I. E. Davidson, Application of Dynamic Voltage Restorer for Power Quality Improvement in Low Voltage Electrical Power Distribution Network: An Overview. International Journal of Engineering Research in Africa, 28 (2017) 142-156.

DOI: 10.4028/www.scientific.net/jera.28.142

Google Scholar

[20] IEEE recommended practice for monitoring electric power quality, IEEE spectrum, IEEE Std. 1159-1995.

Google Scholar