A Resonant Frequency Measurement System for Osseointegration Trans-Femoral Implant

Article Preview

Abstract:

The osseointegration trans-femoral implant is a new orthopedic anchoring method to attach prosthetic limb. The success of this technique depends on how healthy the osseointegration between implant and bone can be achieved and how the post-surgical rehabilitation is progressed. The current clinical practice is based on patient fitness feeling. To achieve a high success rate of osseointegration and an optimal rehabilitation process, a quantitative measurement of the degree of osseointegration is required. In this paper, the authors present a non-invasive method to determine the stability of an osseointegration trans-femoral implant system. It uses resonant frequency of implant system to observe the integration between the implant and bone. The vibration signals of a trans-femoral implant system were collected using an accelerometer attached to the implant abutment and analyzed using Fast Fourier Transform (FFT). The results of in vitro tests are presented to demonstrate that the developed instrument system can be used in future in vivo clinical research.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 295-296)

Pages:

139-144

Citation:

Online since:

October 2005

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2005 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] K. Hagberg and R. Branemark: Prosthetics and Orthotics International, Vol. 25 (2001), p.186.

Google Scholar

[2] R.K. Lippmann: J. Bone Jt Surg., Vol. 14 (1932), p.118.

Google Scholar

[3] L.D.M. Nokes: Proc Instn Mech Engrs, Vol. 213 (1999), p.271.

Google Scholar

[4] N. Meredith: International Journal of Prosthodontics, Vol. 11 (1998), p.491.

Google Scholar

[5] H.M. Huang, S.Y. Lee, C.Y. Yeh, M.S. Wang, W.J. Chang and C.T. Lin: Biomedical Engineering Society, Vol. 29 (2001), p.915.

Google Scholar

[6] A.P. Georgiou and J.L. Cunningham: Clinical Biomechanics, Vol. 16 (2001), p.315.

Google Scholar

[7] W.T. Thomson: Free Vibration: Theory of Vibration with Applications, 3 rd Edition (PrenticeHall Inc., New York).

Google Scholar

[8] N. Meredith, D. Alleyne and P. Cawley: Clinical Oral Implants Research, Vol. 7 (1996), p.261.

Google Scholar

[9] P.L.S. Li, N.B. Jones and P.J. Gregg: Journal of Bone and Joint Surgery, Vol. 77-B (1994), p.640.

Google Scholar

[10] L. Nokes, W.J. Mintowt-Czyz, J.A. Fairclough, I. Machie and J. Williams: J. Biomed Eng., Vol. 7 (1985), p.40.

Google Scholar