Existing models for the concrete confined show a great respect in terms of effectiveness of confinement. The concrete confinement which consists in preventing these strains can be carried out either by an external envelope, or by a weak spacing between the stirrups. All models consist of some modification factors multiplying the unconfined concrete properties; these modification factors depend on the strength ratio and the confinement level. The relation of the ultimate strength ‘and ultimate strain in many existing models is complexity by representing. Each author gauges his model according to the experimental data. In this study, we present the results of a parametric analysis of some the most used models of confinement. The results show that the models of confinement have an important disparity between the values of the strength (fCC) and axial ultimate strain (εcc) of confined concrete.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1-14

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] JG. MacGregor., Reinforced concrete: Mechanics and design. 3rd ed, 1997; 393.

Google Scholar

[2] M, Saafi, A.H. Toutanji, and Z. Li, Behaviour of Concrete Columns Confined with Fibre Reinforced Polymer Tubes, ACI Materials Journal, Vol. 96, No. 4, Ju1. -AUg. 1999, 500-509 pp.

Google Scholar

[3] S. A., Sheikh, S. M. Uzumeri, Strength and Ductility of Tied Concrete Columns, Journal of the Structural Division, ASCE, Vol. 106, No ST5, May 1980, 1079-1102 pp.

DOI: 10.1061/jsdeag.0005416

Google Scholar

[4] F.E. Richart, A. Brandtzaeg, R.L. Brown, A Study of the Failure of Concrete under Combined Compressive Stresses, University of Illinois, Engineering Experimental Station, Urbana, 1928, Bulletin no 185, 104 p.

Google Scholar

[5] R. Benzaid, N. E. Chikh, H. Mesbah, Behaviour of square concrete column confined with GERP composite wrap, Journal of civil engineering and management, 2008, 14 (2), 115-120.

DOI: 10.3846/1392-3730.2008.14.6

Google Scholar

[6] L. Lam, J.G. Teng, . Design-Oriented Stress-Strain Model for FRP-Confined Concrete in Rectangular Columns, Journal of Reinforced Plastics and Composites 2003; 22; pp.1149-1186.

DOI: 10.1177/0731684403035429

Google Scholar

[7] M. Samaan ., A. Mirmiran ., M. Shahawy , Modeling of Concrete Confined by Fiber Composites,. Journal of Structural Engineering, ACSE, 124(9): 1025–1031. (1998).

DOI: 10.1061/(asce)0733-9445(1998)124:9(1025)

Google Scholar

[8] S.A. Sheikh., V. Shahd., S.S. Khoury., Confinement of High-strength Concrete Columns, A CI Structural Journal, 91 (1), 100-111. (1994).

Google Scholar

[9] K. Ait tahar, A. Chateauneuf , Confinement of the Concrete Structures by Embedded Composite Grids', journal Key Engineering Materials Vol. 425, 2010 pp.195-216.

DOI: 10.4028/www.scientific.net/kem.425.195

Google Scholar

[10] V.M. Karbahari, D.A. Eckel., Strengthening of Concrete Column Stubs Through Resin Infused Composite Wraps,. Journal of Thermoplastic Composite Materials, 6(2): 92–107. (1993).

DOI: 10.1177/089270579300600201

Google Scholar

[11] JB. Mander, MJN. Priestley, R. Park., Theoretical stress strain model for confined concrete. J struct Eng 1988; 114(8): 1804-49.

DOI: 10.1061/(asce)0733-9445(1988)114:8(1804)

Google Scholar

[12] MN. Fardis, HH. Khalili., FRP-encased concrete as a structural material. Mag Concrete Res 1982; 34(12): 191-202.

DOI: 10.1680/macr.1982.34.121.191

Google Scholar

[13] A. Mirmiran , M. Shahawy., Behavior of concrete columns confined by fiber composites. Journal of Structural Engineering. ASCE 1997; Vol. 123. No. 5, 583-590.

DOI: 10.1061/(asce)0733-9445(1997)123:5(583)

Google Scholar

[14] K Miyauchi, S. Inoue, T. Kuroda, A. Kobayashi., Experimental study on the confinement effect of concrete cylinders confined by carbon fibber sheets. Proc Jpn Conc Inst 2001; 23 (1): 856-70.

Google Scholar

[15] HA Toutanji. Stress strain characteristics of concrete columns confined with advanced fibber composite sheets. ACI Mater J1999 ; (5-6): 397-404.

Google Scholar