Optical Design of Endoscopic Telecentric Measuring Apparatus

Article Preview

Abstract:

Endoscopic telecentric apparatus is a precision measuring instrument which consists of optical, mechanical and electrical technologies. It can be applied in real-time accurate test to detect the position, shape and wall surface defects of brake master cylinder. This paper designed an optical system with Zemax, it can be used in endoscopic telecentric apparatus. The system has 4mm linear field of view, the line of vision is 90°,the magnification is 0.75×,the depth of field is 6mm.The value of modulation transfer function (MTF) is close to the diffraction limit, the resolution of the system is up to 3 and the spot diagrams of all configurations are smaller than Airy disk, the total track is less than 300mm. It adopts 1/6CCD to receive image, the measurement accuracy reaches to 0.03mm.The system uses pentagonal prism to realize 90°line of vision, it is convenient to assemble and avoids the mirror image. The image quality is good and the design meets the requirement.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

325-328

Citation:

Online since:

May 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wu Fu-tian, Feng Wen-shu. The design principles about CCD size measurement optical system. Applied Optics. 1994,5:20~24

Google Scholar

[2] Wang Zhi-hong. Brake master cylinder compensation hole measuring instrument:[Journal] Changchun University of Science and Technology Department of Mechanical and Electronic Engineering,2007.

Google Scholar

[3] Zhang De-yang. Endoscopics[M]. Beijing: People's health press,2001.(in Chinese)

Google Scholar

[4] Zhao Qiu-ling, WANG Xia, GUAN Li-qiang. Optical System for Stomatology Endoscope with 90°Line of Vision[J] Acta Photonica Sinica, 2009, 38(6):1482-1485. (in Chinese with an English abstract)

Google Scholar

[5] Wang Zhi-jiang, GU Pei-sen. Modern Optical Application Technology Handbook[M].Beijing: China Machine Press, 2009.(in Chinese)

Google Scholar

[6] Zhang Yi-mo. Opertical application[M].Beijing: Publishing House of Electronics Industry, 2008.(in Chinese)

Google Scholar

[7] Liu Jun, Gao Ming. Optical Design[M].Xi'an: Xi'an University press,2006. (in Chinese)

Google Scholar

[8] Zhou Hai-xian, Cheng Yun-fang. Optical System Design[M]. Beijing: China Machine Press,2009.(in Chinese)

Google Scholar