Analysis of Crack in Kaplan Turbine Blade

Article Preview

Abstract:

The paper deals with the analysis of the crack detected in the Kaplan turbine blade. In order to keep the blade integrity the sample was removed by using small sample method. Fractographic and metallographic analyses were used to determine the cause of a detected crack appearance and propagation. The material of the turbine blade was made in 1937 and its structure containing numerous eutectic sulphide inclusions corresponded to the steelmaking technology of that time. Numerous occurrences of sulphide inclusions and sulphide eutectics were identified as the main cause of material failure. Regardless of these non-metallic inclusions the blade was repaired by welding and nowadays the repaired blade has been under safe operation for more than 9 years.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

131-134

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] http://www.enviweb.cz/clanek/voda/47251/nejvetsi-vyrobci-vodnich-turbin-v-cr

Google Scholar

[2] Small Punch Test Method for Metallic Materials. Part B: A Code of Practice for Small Punch Testing for Tensile and Fracture Behaviour. CEN/WS21, 21.12.2005.

Google Scholar

[3] K. Levíček, K. Stránský, Metalurgické vady ocelových odlitků, SNTL. Praha. 1984, 186-190.

Google Scholar

[4] J. Koutský, F. Jaroš, K. Vojtěch, Lomy ocelových konstrukcí, STNL. Praha. 1976, 185-1193.

Google Scholar