Specific Detection of Staphylococcus Enterotoxin B in Milk Using Piezoresistive Cantilever Aptasensor

Article Preview

Abstract:

In this paper, an aptasensor with high sensitivity and rapid response was developed for the detection of staphylococcus enterotoxin B (SEB) by using thiol-modified piezoresistive cantilever. Thiol-modified aptamers, acting as the functionalized sensing elements, were immobilized on the nanogold-coated surface of the sensing cantilever as agents for detecting SEB. By using the functionalized aptasensors, different concentrations of SEB were detected with a wide detection range of 6-100 ng/mL and a quick response in milk. The experimental results indicated that the cantilever-based aptasensors had sufficient sensitivity for the detection of SEB in real food commodities and might provide an economical platform for on-site detections of different toxicants with the advantages of portability, high sensitivity, and rapid response.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 645-646)

Pages:

1298-1302

Citation:

Online since:

May 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] E. J. Schantz, W. G. Roessler, J. Wagman, L. Spero, D. A. Dunnery, and M. S. Bergdoll, Purification of Staphylococcal Enterotoxin B, Biochemistry, vol. 4, no. 6, pp.1011-1016, (1965).

DOI: 10.1021/bi00882a005

Google Scholar

[2] G. A. Campbell, M. B. Medina, and R. Mutharasan, Detection of Staphylococcus enterotoxin B at picogram levels using piezoelectric-excited millimeter-sized cantilever sensors, Sens. Actuators B, Chem., vol. 126, no. 2, pp.354-360, (2007).

DOI: 10.1016/j.snb.2007.03.021

Google Scholar

[3] L. Wu, B. Gao, F. Zhang, X. Sun, Y. Zhang, and Z. Li, A novel electrochemical immunosensor based on magnetosomes for detection of staphylococcal enterotoxin B in milk, Talanta, vol. 106, pp.360-366, Mar. (2013).

DOI: 10.1016/j.talanta.2012.12.053

Google Scholar

[4] D. Maraldo and R. Mutharasan, Detection and Confirmation of Staphylococcal Enterotoxin B in Apple Juice and Milk Using Piezoelectric-Excited Millimeter-Sized Cantilever Sensors at 2. 5 fg/mL, Anal. Chem., vol. 79, no. 20, pp.7636-7643, (2007).

DOI: 10.1021/ac070589l

Google Scholar

[5] T. Alefantis, P. Grewal, J. Ashton, A. S. Khan, J. J. Valdes, and V. G. Del Vecchio, A rapid and sensitive magnetic bead-based immunoassay for the detection of staphylococcal enterotoxin B for high-through put screening, Molecular Cell Probes, vol. 18, no. 6, pp.379-382, Dec. (2004).

DOI: 10.1016/j.mcp.2004.06.003

Google Scholar

[6] K. E. Sapsford, J. Francis, S. Sun, Y. Kostov, and A. Rasooly, Miniaturized 96-well ELISA chips for staphylococcal enterotoxin B detection using portable colorimetric detector, Anal. Bioanal. Chem., vol. 394, no. 2, pp.499-505, May (2009).

DOI: 10.1007/s00216-009-2730-z

Google Scholar

[7] J. -H. Han, H. -J. Kim, L. Sudheendra, S. J. Gee, B. D. Hammock, and I. M. Kennedy, Photonic crystal lab-on-a-chip for detecting staphylococcal enterotoxin B at low attomolar concentration, Anal. Chem., vol. 85, no. 6, pp.3104-3109, Mar. (2013).

DOI: 10.1021/ac303016h

Google Scholar

[8] E. Temur, A. Zengin, I. H. Boyaci, F. C. Dudak, H. Torul, and U. Tamer, Attomole sensitivity of staphylococcal enterotoxin B detection using an aptamer-modified surface-enhanced Raman scattering probe, Anal. Chem., vol. 84, no. 24, pp.10600-10606, Dec. (2012).

DOI: 10.1021/ac301924f

Google Scholar

[9] Y. Du, B. Li, and E. Wang, Fitting" Makes "Sensing, Simple: Label-Free Detection Strategies Based on Nucleic Acid Aptamers, Accounts. Chem. Res., vol. 46, pp.203-213, Nov. (2013).

DOI: 10.1021/ar300011g

Google Scholar

[10] S. Wu, N. Duan, X. Ma, Y. Xia, H. Wang, and Z. Wang, A highly sensitive fluorescence resonance energy transfer aptasensor for staphylococcal enterotoxin B detection based on exonuclease-catalyzed target recycling strategy, Anal. Chim. Acta., vol. 782, pp.59-66, Jun. (2013).

DOI: 10.1016/j.aca.2013.04.025

Google Scholar

[11] J. Fritz, Cantilever biosensors, Analyst, vol. 133, no. 7, pp.855-863, Jul. (2008).

Google Scholar

[12] J. A. DeGrasse, A Single-Stranded DNA Aptamer That Selectively Binds to Staphylococcus aureus Enterotoxin B, PLoS One, vol. 7, no. 3, p. e33410, (2012).

DOI: 10.1371/journal.pone.0033410

Google Scholar