Finite Element Analysis of Surface Modification of Titanium Alloy Used for Hip Implant

Article Preview

Abstract:

Titanium and its alloys, especially Ti-6Al-4V have found application as hip implants due to their mechanical properties, excellent biocompatibility, and corrosion resistance. The use of cementless hip implants has increased over the years as it is thought that this type is more durable compared to cemented hip implants. Cementless hip implants have a porous surface that allows the bone to grow into it and form a strong bone–implant connection. The goal of this study is the use of Finite Element Method simulations to obtain information about how different types of surface topography of a TI-6Al-4V hip implant affect the shear stress, which is used to access the bone-implant connection. Finite Element Analysis is used to analyze the stress distribution in three simple surface modifications in a hip implant under different types of loads. The optimal surface modification out of these three is obtained based on the shear stress distribution, as it is known that lower shear stress promotes bone ingrowth. In this study, we have considered the interaction between cortical bone and implant surface. Material properties and boundary conditions used for the simulations have been adapted from literature.

You might also be interested in these eBooks

Info:

Periodical:

Materials Science Forum (Volume 1016)

Pages:

1544-1548

Citation:

Online since:

January 2021

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2021 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] C Y Hu, T-R Yoon, Recent updates for biomaterials used in total hip arthroplasty, Biomater. Res. 22 (2018) 33.

DOI: 10.1186/s40824-018-0144-8

Google Scholar

[2] J. M. I. Loberg, S. Hansson, E. Ahlberg, Characterisation of titanium dental implants I: Critical assessment of surface roughness parameters, The Open Biomaterials Journal, 2, 2010, 1–8.

DOI: 10.2174/1876502501002010018

Google Scholar

[3] Y. Noyama, T. Nakano, T. Ishimoto, T. Sakai, H. Yoshikawa, Design and optimization of the oriented groove on the hip implant surface to promote bone microstructure integrity, Bone, 52(2), 2013, 659-667.

DOI: 10.1016/j.bone.2012.11.005

Google Scholar

[4] R. H. Mattila, P. Laurila, J. Rekola, J. Gunn, L. V. Lassila, T. Mäntylä, A. J. Aho, P. K. Vallittu, Bone attachment to glass-fibre reinforced composite implant with porous surface, Acta biomaterialia, 5, 2009, 1639-1646.

DOI: 10.1016/j.actbio.2009.01.020

Google Scholar

[5] S. Das, S. K. Sarangi, Finite Element Analysis of Femur Fracture Fixation Plates, International Journal of Basic and Applied Biology, 1(1), 2014, 1-5.

Google Scholar

[6] K. S. S. Aradhya, M. R. Doddamani, Characterization of Mechanical Properties of SiC/Ti-6Al-4V Metal Matrix Composite (MMC) Using Finite Element Method, American Journal of Materials Science, 5(3C), 2015, 7-11.

Google Scholar

[7] A. Vulović, N. Filipović, Computational analysis of hip implant surfaces, Journal of the Serbian Society for Computational Mechanics, 13(1), 2019, 109-119.

DOI: 10.24874/jsscm.2019.13.01.07

Google Scholar