Failure Analysis of a Damaged Helicopter Rescue Hoist Cable
Abstract:
This paper presents the results and main conclusions of a study made to analyze the cause of failure occurred with an austenitic 304 class stainless steel wire rope of a helicopter rescue hoist. The cable is made up of 19 strands, 12 outside and 7 inside. As each strand contains 7 wires, the whole cable is made up of 133 wires. The study includes the chemical and microstructural characterization of the material, as well as the determination of its hardness, mechanical properties and the fractographic analysis by scanning electron microscopy (SEM). Tensile tests were performed for three velocities simulating different work conditions: 250mm/min, 50mm/min and 5mm/min. The fractographic analysis shows that the cable suffered lateral loss of material due to friction and leading to the failure of the remaining material by ductile mode.