Geometrical Micropillars Combined with Chemical Surface Modifications – Independency of Actin Filament Spatial Distribution in Primary Osteoblasts

Article Preview

Abstract:

Cell-biomaterial interactions are strongly affected by topographical and chemical surface characteristics. We found out earlier that geometric titanium (Ti) pillar structures in the micrometer range induce the cells to rearrange their actin cytoskeleton in short fibers solely on the top of the pillars. As a result, cell physiology was hampered concerning collagen I synthesis and spreading capacity. Furthermore, the position-dependent initial cell adhesion strength was declined near the edges. We asked whether these observed cellular effects can be performed only in combination with Ti or occur independently of chemical surface features. In addition, the specific culture conditions, e.g. serum content or influence of gravity, were of interest. Human primary osteoblasts were cultured in Osteoblast Growth Medium with serum containing SupplementMix on pure silicon pillars (5x5x5 μm) or on samples additionally sputtered with Ti (as reference) or gold. To offer the cells ligands for their adhesion receptors, we coated the pillars with collagen I or alternatively with a plasma polymer layer from allylamine. Different from standard culture conditions, the cells were cultured against gravity as well as without serum. The actin cytoskeleton was stained with phalloidin-TRITC after 24 h and analyzed by confocal laser scanning microscopy. Interestingly, on all modifications tested the cell’s actin cytoskeleton was distinctly organized in short fibers on the top of the pillars. Thus, we were able to exclude the influence of (i) the material chemistry (gold, silicon, physical plasma vs. Ti), (ii) the protein deposition on the pillar top and edges, and (iii) the impression caused by gravity.

You might also be interested in these eBooks

Info:

Periodical:

Materials Science Forum (Volumes 783-786)

Pages:

1320-1325

Citation:

Online since:

May 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] J.B. Nebe, F. Luethen, B. Finke, C. Bergemann, K. Schroeder, J. Rychly, K. Liefeith, A. Ohl, Improved initial osteoblast functions on amino-functionalized titanium surfaces, Biomol. Eng. 24 (2007) 447-454.

DOI: 10.1016/j.bioeng.2007.07.004

Google Scholar

[2] J.B. Nebe, F. Luethen, J. Rychly, Topology-dependent cellular interactions - Cell structure-cell function dependence on titanium surfaces, in: Metallic Biomaterial Interactions, Eds.: J. Breme, C.J. Kirkpatrick, R. Thull, WILEY-VCH, 2008, pp.215-222.

Google Scholar

[3] M. Jaeger, C. Zilkens, K. Zanger, R.J. Krauspe, Significance of nano- and microtopography for cell-surface interactions in orthopaedic implants, Biomed. Biotechnol. 2007 (8) 69036.

DOI: 10.1155/2007/69036

Google Scholar

[4] D.W. Hamilton, D.M. Brunette, The effect of substratum topography on osteoblast adhesion mediated signal transduction and phosphorylation, Biomaterials 10 (2007) 1806-1819.

DOI: 10.1016/j.biomaterials.2006.11.041

Google Scholar

[5] B. Geiger, J.P. Spatz, A.D. Bershadsky, Environmental sensing through focal adhesions. Nat. Rev. Mol. Cell Biol. 10 (2009) 21-33.

DOI: 10.1038/nrm2593

Google Scholar

[6] K. Anselme, M. Bigerelle, Modelling approach in cell/material interactions studies, Biomaterials 27 (2006) 1187-1199.

DOI: 10.1016/j.biomaterials.2005.10.009

Google Scholar

[7] C. Matschegewski, S. Staehlke, R. Loeffler, R. Lange, F. Chai, D.P. Kern, U. Beck, J.B. Nebe, Cell architecture-cell function dependencies on titanium arrays with regular geometry, Biomaterials 31 (2010) 5729-5740.

DOI: 10.1016/j.biomaterials.2010.03.073

Google Scholar

[8] C. Matschegewski, S. Staehlke, H. Birkholz, R. Lange, U. Beck, K. Engel, J.B. Nebe, Quantitative analysis of the cell phenotype and actin organisation in osteoblasts on controlled surface topography, Materials 5 (2012) 1176-1195.

DOI: 10.3390/ma5071176

Google Scholar

[9] H. Rebl, B. Finke, R. Lange, K. -D. Weltmann, J.B. Nebe, Impact of plasma chemistry versus titanium surface topography on osteoblast orientation, Acta Biomater. 8 (2012) 3840-3851.

DOI: 10.1016/j.actbio.2012.06.015

Google Scholar

[10] F. Luethen, R. Lange, P. Becker, J. Rychly, U. Beck, J.B. Nebe, The influence of surface roughness of titanium on β1- and α3-integrin adhesion and the organization of fibronectin in human osteoblastic cells. Biomaterials 26 (2005) 2423-2440.

DOI: 10.1016/j.biomaterials.2004.07.054

Google Scholar