Application of 0.8 Design Factor in China Gas Pipeline

Article Preview

Abstract:

The paper reviews current situation of high design factor application abroad, and analyzes development of high-strength pipeline in China. It shows that related technology has greatly improved in China, such as manufacture of high strength pipe, inspection, quality control, pipeline construction and pipeline integrity management. So it is available to use 0.8 design factor for the class one location in China. And the paper also introduces trial section experiences in the third West-East pipeline on safety pre-assessment, design check, pipe specification, construction technology and integrity management plan. With relative specifications further perfected, it is promising to put the 0.8 design factor into a wide use in Chinese pipeline project.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

965-974

Citation:

Online since:

January 2019

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2019 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] PHIL Hopkins. High design factor pipelines: integrity issues [J].Journal of Pipeline Integrity, 2005, 4(2): 69-97.

Google Scholar

[2] CSA Z662-2007: Oil and gas pipeline systems[S]. Canadian Standards Association, (2007).

Google Scholar

[3] ASME B31.8S: Managing system integrity of gas pipeline[S]. New York: ASME B31 Committee, (2001).

Google Scholar

[4] 49 CFR 192: Transportation of natural and other gas by pipeline :minimum federal safety standards[S], Pipeline and Hazardous Materials Safety Administration(PHMSA), Department of Transportation(DOT).Published by Office of the Federal Register National Archives and Records administration, (2010).

DOI: 10.4135/9781544377230.n134

Google Scholar

[5] AS 2885.1: Pipelines—Gas and liquid petroleum Part 1 Design and construction[S], Australian standards, (2007).

Google Scholar

[6] Ministry of Construction of People's Republic of China. GB 50251-2015: Code for design of gas transmission pipeline engineering[S]. Beijing: China Planning Press, (2015).

Google Scholar

[7] Zhao Xinwei, Zhang Guangli1, Luo Jinheng, et al. Impact of Improving Design Factor over 0.72 on the Safety and Reliability of Gas Pipelines and Feasibility Justification [J]. CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2012, 25(1): 166–172.

DOI: 10.3901/cjme.2012.01.166

Google Scholar

[8] Petrochina pipeline construction project management department. Q/SY GJX 117-2012: Technical specification of X80 SAWH line pipe for 0.8 design factor section in the 3rd west-east pipeline project [S], Beijing: Petroleum Industry Press, (2012).

DOI: 10.1115/ipc2010-31058

Google Scholar