Search Options

Sort by:

Sort search results by

Publication Type:

Publication Type filter

Open access:

Publication Date:

Periodicals:

Periodicals filter

Search results

Online since: July 2015
Authors: Tie Kun Jia, Jian Liang Cao, Guang Sun, Zhan Ying Zhang
All the diffraction peaks can be indexed to be hexagonal SnS2 according to the standard XRD data file standard values (JCPDS File No. 23-0677).
Madras, Kinetics of simultaneous photocatalytic degradation of phenolic compounds and reduction of metal ions with nano-TiO2, Environ.
Online since: May 2014
Authors: Chang Woo Lee, Yong Ho Ko, Jung Hwan Bang, Young Ki Ko
Wire bonding technology, however, can cause reduction in the integration density and aggravation in the high frequency -performance of the stack module.
[8] JC Eloy, Market trends & Cost analysis for 3D ICs, Yole development report 2007 [9] Thomas Richardson, Chen Wang, Yun Zhang, Defect Free, Fast TSV Fill, Presentation of PEAKS Conference 20072009 Yole Roadmap Data [10] Peter A.
Online since: May 2014
Authors: Andrzej Rosochowski, Evgenia Yakushina, Aleksey Reshetov
Some considerations regarding temperature effect on DB of UFG material It should be noted that DB of Ti-6Al-4V was carried out at reduced temperature, compared with literature data.
The reduction of DB temperature down to 825°C at low pressure of 3.2 MPa, was achieved in UFG condition, which is 50°C lower than the temperature of DB achieved in the up to date publications.
Online since: November 2012
Authors: Vladimir Slugeň, Jarmila Degmová, Jana Veterníková, S. Kilpeläinen, F. Tuomisto, V. Kršjak
The fit variant (the reduction of chi-square) achieved a value in a range (1; 1.1), which means that the goodness of the fit was sufficient and the relative fit deviation was below 0.1%.
The MBN data are presented by the BNA values, according to which the presence of defects, residual stress or hardness for each material, respectively, can be compared.
Online since: November 2014
Authors: Andrzej Zbrowski, Stanisław Kozioł
In the case of ventilation systems using recuperators, the effective functioning and safety of the object conditioned is affected by the efficiency of the heat exchanger, as well as its tightness, the resistance of air streams, and also the phenomenon of the freezing of the condensed humidity at subzero temperatures of the outside air, leading to the reduction in the exhaust air stream and icing.
All measurement units and actuators are connected to a control system and a data collection and processing system in a way enabling automatic execution of the following basic tasks: - The reading of the indications of measurement sensors and verification of their operation; - Control over systems and actuators (cooling system, valves, heaters, humidifier, fans, etc.); and, - The independent stabilization of streams, temperature, and humidity of the air supplied from both sides of the recuperator.
Online since: September 2013
Authors: Ji Bai Wang, Ming Liang Ni
In the project in South Africa, there are significant reductions in several major indicators after pretreatment with 333 BV (DOC from 17.0mg/L to 4.4 mg/L; color from 315 to 76; UVA254 from 3.453 to 0.388) [6].
If more specific data on MIEX resin can be released as so entire process can be optimized to suit different characteristics of industrial wastewater, MIEX resin will obtain a great application on aspect of wastewater treatment with its remarkable capability.
Online since: June 2015
Authors: Ying Ping Liao, Wen Bin Yao, Zhi Zhang, Yi Liu, Lin Liu, Zhi Hui Yang, Li Yuan Chai
By comparing the experimental data in both literatures, Fe(III) sulfate was more efficient than Fe(II) sulfate.
Loeppert, Arsenite and arsenate adsorption on ferrihydrite: Surface charge reduction and net OH- release stoichiometry, Environmental Science & Technology, 33 (1999) 1179-1184
Online since: December 2013
Authors: Kamdi Zakiah, P.H. Shipway, K.T. Voisey
The scars were scanned using a contact probe with spacing of data points of 1 µm in the scan direction and with a 10 µm spacing between adjacent scans.
Preferential binder removal is clearly seen in the WC-Co coating following abrasion with all abrasive types, but carbide damage becomes less apparent with reduction in the abrasive hardness from silicon carbide to alumina and silica (Fig. 4).
Online since: February 2013
Authors: Chen Xi Wang, Jing Zhu, Cheng Jun Zhang, Shi Kai Zhang
The data of the example as table 3 shows, m(A), m(B) and m(C) is the BBM of all evidences on the target A, B, C.
In addition, through the reduction of result uncertainty.
Online since: July 2019
Authors: Ling Wang, Hao Wu, Rui Jun Gao, Yan Yao
The adiabatic temperature rise data is collected automatically by the computer at the interval time of 30 min.
The maximum crack width of concrete with SRA at 5% dosage is 0.342 mm compared to the reference sample is 0.875 mm, the reduction as high as 61%.
Showing 38061 to 38070 of 40699 items