The Effect of Abscission of Insulation Lining of Electromagnetic Flowmeter on Output Signal

Article Preview

Abstract:

In pipe of electromagnetic flowmeter must be installed internal insulation lining to prevent the electromagnetic flowmeter signal is short circuit by metal pipe. However, in the process of using the electromagnetic flow meter, insulation lining is easy to fall off because of the fluid temperature and pressure changes, thus lead to the output signal of the electromagnetic flowmeter is changed. The effect of electromagnetic flowmeter insulation lining fall off to the output signal is analyzed by the theory of electromagnetic flow meters weight function. Get the relationship of the output signal and the insulation lining drop area and position. The paper provides a theoretical analysis method for the effect abscission of insulation lining of electromagnetic flow meter on output signal.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1910-1915

Citation:

Online since:

November 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] W.C. Cai. electromagnetic flowmeter.Beijing:China petrochemical press,1981.(In Chinese)

Google Scholar

[2] Shercliff. J. A. The Theory of Electro-magnetic Flow Measurement. Cambridge University Press, 1962.

Google Scholar

[3] X.D. Sun, B.Li, and Z.F. Zhao.Researches on a new Dry Calibration Method of Electromagnetic Flowmeter Based on Unit Element. I2MTC 2009-IEEE International Instrumentation and Measurement Techhnology Conference Proceeedings,2009.5,pp.270-273.

DOI: 10.1109/imtc.2009.5168457

Google Scholar

[4] Bevir M K. The theory of induced voltage electromagnetic flowmeter. Fluid Mech.1970, Vol.43,pp.77-590.

Google Scholar

[5] K.X. Wei. Research on the sensor technologies of electro- magnetic flow measurement in partially filled pipes (Ph.D.Shanghai University,China 2009),pp.19-24 (In Chinese)

Google Scholar

[6] J.Z. Chen. Fundamental Research on the New Type Multi-electrode Insertion Electromagnetic FlowSensor(Ph.D.Shanghai University,China2009),pp.93-114 (In Chinese)

Google Scholar

[7] Hussain Y A,Baker R C. Optimised noncontact electromagnetic flowmeter.phys. E: Sci. Instrum, 1985,18,pp.210-213.

DOI: 10.1088/0022-3735/18/3/010

Google Scholar

[8] Roger C Baker.On the concept of virtual current as a means to enhance verification of electromagnetic flowmeters. Measurement Science and Technology 2011,pp.10-20.

DOI: 10.1088/0957-0233/22/2/109501

Google Scholar

[9] Tavoularis S. Measurement in Fluid Mechanics. Cambridge: Cambridge University Press, 2005.

Google Scholar

[10] Baker R.C. Moore P.L., Thomasa. Electronic verification of flowmeters in the water industry. Water management, 2006,4,pp.245-251.

Google Scholar

[11] X.FU, L.HU and H.B. Xie. Dry calibration technique of electromagnetic flowmeters. Chinese journal of mechanical engineering,2007.6.Vol.43,No.6,pp.26-30. (In Chinese)

DOI: 10.3901/jme.2007.06.026

Google Scholar

[12] J. Hemp,I. Youngs. Problems in the theory and design of electromagnetic flowmeters for dielectric liquids. Part 3a. Modelling of zero drift due to flux linkage between coil and electrode cables. Flow Measurement and Instrumentation.2003.Vol.14, No.3,pp.65-78.

DOI: 10.1016/s0955-5986(03)00017-7

Google Scholar