Simultaneous Measurement of Strain and Temperature with Hollow Core Fiber Based Intermodal Interferometer

Article Preview

Abstract:

A hollow core fiber based all-fiber intermodal interferometer is proposed for measurement of strain and temperature. The sensing structure is simply a short segment of hollow core silica fiber being spliced between two normal single mode fibers. The fabrication process only involves a conventional fusion splicer and a mechanical fiber cleaver. Experimental results show that sensitivities of-1.21 pm/με and 21.30 pm/°C are achieved for strain and temperature measurements, respectively.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

231-236

Citation:

Online since:

June 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] W. J. Bock, T. A. Eftimov, P. Mikulic, J. Chen, "An inline core-cladding intermodal using a photonic crystal fiber," Journal of Lightwave Technology, vol. 27, SEP. 2009, pp.3933-3938, doi: 10.1109/ JLT.2009.2021282.

DOI: 10.1109/jlt.2009.2021282

Google Scholar

[2] H. P. Gong, C. C. Chan, Y. F. Zhang, W. C. Wong, X. Y. Dong , "Miniature refractometer based on modal interference in a hollow-core photonic crystal fiber with collapsed splicing," Journal of Biomedical Optics, vol. 16, JAN. 2011, pp.14-17.

DOI: 10.1117/1.3527259

Google Scholar

[3] T. Dudena, V. Radmilovica, "High sensitivity resonance frequency measurements of individual microcantilevers using fiber optical interferometry," Review of Scientific Instruments, vol. 80, MAR.2009, pp.023706-023709.

DOI: 10.1063/1.3079686

Google Scholar

[4] D. Wu, T. Zhu, M. Deng, D.-W. Duan, L.-L. Shi, J. Yao, Y.-J. Rao, "Refractive index sensing based on Mach–Zehnder interferometer formed by three cascaded single-mode fiber tapers," Applied Optics , vol.50 , APR.2011, pp.1548-1553, doi: 138004.

DOI: 10.1364/ao.50.001548

Google Scholar

[5] W. C. Wong, C. C. Chan, H. P. Gong, K. C. Leong, "Mach–Zehnder Photonic Crystal Interferometer in Cavity Ring-Down Loop for Curvature Measurement," IEEE Photonics Technology Letters, vol. 23,2011, pp.795-797.

DOI: 10.1109/LPT.2011.2132796

Google Scholar

[6] O. Frazão, J. Viegas, P. Caldas, J. L. Santos, F. M. Araújo, L. A. Ferreira, F. Farahi, "All-fiber Mach-Zehnder curvature sensor based on multimode interference combined with a long-period grating," Optics Letters, vol. 32, NOV.2007, pp.3074-3976, doi: 85935.

DOI: 10.1364/ol.32.003074

Google Scholar

[7] Y. Zhou, W.J. Zhou, C.C. Chan, W.C. Wong , L.-Y. Shao, J. Cheng, X.Y. Dong, "Simultaneous measurement of curvature and temperature based on PCF-based interferometer and fiber Bragg grating," Optics Communications, vol. 284, SEP.2011, p.5669–5672.

DOI: 10.1016/j.optcom.2011.08.048

Google Scholar

[8] L. V. Nguyen, D. H wang, S. Moon, D. S. Moon, Y. Chung, "High temperature fiber sensor with high sensitivity based on core diameter mismatch," Optics Express, vol. 16, JUL.2008, pp.11369-11375.

DOI: 10.1364/oe.16.011369

Google Scholar

[9] W. J. Zhou, W. C. Wong, C. C. Chan, L.-Y Shao, X. Y. Dong, "Highly sensitive fiber loop ringdown strain sensor using photonic crystal fiber interferometer," Applied Optics,vol. 50, JUL.2011, pp.3087-3092, doi: 139184.

DOI: 10.1364/ao.50.003087

Google Scholar

[10] B. Dong, Emily J. H, "Temperature-insensitive and intensity-modulated embedded photonic-crystal-fiber modal-interferometer-based microdisplacement sensor," Journal of Optical Society of America B, vol. 28, OCT.2011, pp.2332-2336, doi: 148196.

DOI: 10.1364/josab.28.002332

Google Scholar

[11] P. J. Mulhern, T. Hubbard, C. S. Arnold, B. L. Blackford, M. H. Jericho, "A scanning force microscope with a fiber-optic-interferometer displacement sensor," Review of Scientific Instruments, vol. 62, May, 1991, pp.1280-1284.

DOI: 10.1063/1.1142485

Google Scholar

[12] J. Villatoro, V. P. Minkovich, V. Pruneri, G. Badenes, "Simple all-microstructured-optical-fiber interferometer built via fusion splicing," Optics Express, vol. 15, FEB.2007, pp.1491-1496.

DOI: 10.1364/oe.15.001491

Google Scholar

[13] X. Y. Dong, L. Su, P. Shum, Y. Chung, and C.C. Chan, "Wavelength-selective all-fiber filter based on a single long-period fiber grating and a misaligned splicing point," Optics Communications, vol. 258, 2006, pp.159-163, doi: 10.1016/j.optcom. 2005.07.075.

DOI: 10.1016/j.optcom.2005.07.075

Google Scholar

[14] Z. B. Tian, S.-H. Yam, H. P. Loock, "Single-Mode Fiber Refractive Index Sensor Based on Core-Offset Attenuators," IEEE Photonics Technology Letters, vol. 20, AUG.2008, pp.1387-1389.

DOI: 10.1109/LPT.2008.926832

Google Scholar

[15] D. Donlagic, E. Cibula, "All-fiber high-sensitivity pressure sensor with SiO2 diaphragm," Optics Letters, vol. 30, AUG.2005, pp.2071-2073.

DOI: 10.1364/ol.30.002071

Google Scholar

[16] H. Y. Choi, K. S. Park, S. J. Park, U.C. Paek, B. H. Lee, E. S. Choi, "Miniature fiber-optic high temperature sensor based on a hybrid structured Fabry-Perot interferometer," Optics Letters, vol. 33, NOV.2008, pp.2455-2457, doi: 99210.

DOI: 10.1364/ol.33.002455

Google Scholar

[17] H. Y. Choi, G. Mudhana, K. S. Park, U.-C. Paek, B. H. Lee, "Cross-talk free and ultra-compact fiber optic sensor for simultaneous measurement of temperature and refractive index," Optics Express, vol. 18, JAN. 2010, pp.141-149.

DOI: 10.1364/oe.18.000141

Google Scholar

[18] E. B. Li, "Temperature compensation of multimode-interference-based fiber devices," Optics Letters, vol. 32, JUL.2007, pp.2064-2066, doi: 81726.

DOI: 10.1364/ol.32.002064

Google Scholar

[19] S. H. Aref, R. Amezcua-Correa, J. P. Carvalho, O. Frazão, P. Caldas, J. L.Santos, F. M. Araújo, H. Latifi, F. Farahi, L. A. Ferreira, J. C. Knight, "Modal interferometer based on hollow-core photonic crystal fiber for strain and temperature measurement," Optics Express, vol. 17, OCT.2009, pp.18669-18675.

DOI: 10.1364/oe.17.018669

Google Scholar

[20] S. Barabach. G, J. P. Carvalho, O. Frazão, J. Olszewski, P. Mergo, J. L. Santos, W. Urbanczyk, "Intermodal interferometer for strain and temperature sensing fabricated in birefringent boron doped microstructured fiber," Applied Optics, vol. 50, JUL.2011, pp.3742-3749, doi: 141936.

DOI: 10.1364/ao.50.003742

Google Scholar