Finite Element Analysis of Multi-Implant Surgery for a Large Area of Defects

Article Preview

Abstract:

This study aimed to confirm the application of multi-implants for mandibles with a large edentulous area using methods of finite element analysis (FEA). 3D finite element models of mandible with multi-implants were generated form reverse engineering of CT images stored in DICOM format. In the FEA of the implant model, the majority of the stress falls onto neck of the titanium implant and is well-distributed around the cylinder body of screw, resulting in less stress being applied to the cortical bone around titanium screw. Under a continual normal force of 100 N, The maximum stress on the cortical bone was located in the area around the titanium implants, and was 111.62Mpa, while the maximum stress on the titanium implant was located at the neck of the implant, and was 120.35 Mpa, much lower than the yield strength of the titanium framework (1260Mpa). The maximum deformation was around 0.65 mm. The deformation of the alveolar bone in our multi-implant model was within the acceptable range. This study show that the titanium screw used for multi-implants meets the requirements in term of physical properties for a large area of defects.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

396-402

Citation:

Online since:

May 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] T.A. Makkonen, S. Holmberg, L. Niemi, C. Olsson, T. Tammisalo, J. Peltola, A 5-year prospective clinical study of Astra Tech dental implants supporting fixed bridges or overdentures in the edentulous mandible, C. Oral Implants R. 8-6 (1997).

DOI: 10.1034/j.1600-0501.1997.080605.x

Google Scholar

[2] R.Z. Deng, Q.G. Hu, Q. Wang, Y.U. Qing, Computer-assisted individualized reconstruction of maxillary defect, Stomatology 1 (2008) 12-4.

Google Scholar

[3] M.S. Block, C. Chandler, Computed tomography-guided surgery: complications associated with scanning, processing, surgery, and prosthetics, J. Oral Maxillofac. Surg. 67-11 (2009) 13-22.

DOI: 10.1016/j.joms.2009.04.082

Google Scholar

[4] W.C. Scarfe, A.G. Farman, P. Sukovic, Clinical applications of cone-beam computed tomography in dental practice, J. Can. Dent. Assoc. 72-1 (2006) 75-80.

Google Scholar

[5] A.W. Hendrikx, T. Maal, F. Dieleman, E.M. Van Cann, M.A. Merkx, Cone-beam CT in the assessment of mandibular invasion by oral squamous cell carcinoma: results of the preliminary study, Int. J. Oral Maxillofac. Surg. 39-5 (2010) 436-439.

DOI: 10.1016/j.ijom.2010.02.008

Google Scholar

[6] T.J. Salinas, V.P. Desa, A. Katsnelson, M. Miloro, Clinical evaluation of implants in radiated fibula flaps, J. Oral Maxillofac. Surg. 68-3 (2010) 524-529.

DOI: 10.1016/j.joms.2009.09.104

Google Scholar

[7] S.E. Quaresma, P.R. Cury, W.R. Sendyk, A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone, J. Oral Implantol. 34-1 (2008) 1-6.

DOI: 10.1563/1548-1336(2008)34[1:afeaot]2.0.co;2

Google Scholar

[8] M.J. Tsai, C.T. Wu, and C.Y. Chen, A study of customized subperiosteal implants employing computer assisted engineering, Adv. info. Sci. and Serv. Sciences 5 (2013) 1030-1036.

Google Scholar

[9] Y.N. Qiu, J.F. Zhou, L. Li, R.F. Bu, H.C. Liu, Analysis of three-dimensional finite element in the abutment design of the palatal subperiosteal implant in the rehabilitation of the unilateral edentulous maxillary defect, Chinese J. of Aesth. Med. 2 (2008).

Google Scholar

[10] Y.N. Qiu, J.F. Zhou, R.F. Bu, H.C. Liu, Construction of the three-dimensional finite element model of defective edentulous cranial-maxillary complex rehabilitated by palatal-subperiosteal-implant-supported prosthesis, Chinese J. of Aesth. Med. 2 (2008).

Google Scholar

[11] J.G. Zhao, Q.B. Zhang, B.Y. Liu, H.Y. Zhang, W.H. Chen, Early and immediate restored and loaded dental implants for anterior tooth, Beij. J. Stomato. 5 (2007) 277-279.

Google Scholar

[12] Z. Lian, H. Guan, S. Ivanovski, Y.C. Loo, N.W. Johnson, H. Zhang, Effect of bone to implant contact percentage on bone remodelling surrounding a dental implant, Int. J. Oral Maxillofac. Surg. 39-7 (2010) 690-698.

DOI: 10.1016/j.ijom.2010.03.020

Google Scholar

[13] M. Motoyoshi, S. Ueno, K. Okazaki, N. Shimizu, Bone stress for a mini-implant close to the roots of adjacent teeth-3D finite element analysis, Int. J. Oral Maxillofac. Surg. 38-4 (2009) 363-368.

DOI: 10.1016/j.ijom.2009.02.011

Google Scholar

[14] R.T. Hart, V.V. Hennebel, N. Thongpreda, W.C. Van Buskirk, R.C. Anderson, Modeling the biomechanics of the mandible: a three-dimensional finite element study, J Biomech. 25-3 (1992) 261-286.

DOI: 10.1016/0021-9290(92)90025-v

Google Scholar

[15] N.R. Kaipatur, M.C. Flores, Accuracy of computer programs in predicting orthognathic surgery soft tissue response, J. Oral Maxillofac. Surg. 67-4 (2009) 751-759.

DOI: 10.1016/j.joms.2008.11.006

Google Scholar