Design and Implementation of the Health Examination Robot Control System Architecture

Article Preview

Abstract:

The paper research a health examination robot, which set height, weight, blood pressure, blood glucose, cholesterol, blood oxygen, electrocardiogram (ECG), energy check in one certain. In the design, adopt 32 bit embedded ARM micro controller NuMicro NUC140, RFID card reader, oxygen check control module and ECG check control module, taking into account the system connection and RFID identification, parameters of historical data query and ECG check process. Experimental data show that system functions are realized and to promote low-cost medical treatment.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

352-359

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Li J M, Wang S X, Wang X F, et al, Optimization of a Novel Mechanism for a Minimally Invasive Surgery Robot[J], Int J Med Robotics Compute Assist Surg, 2010, 6: 83-90.

Google Scholar

[2] Hong bo Wang, Fumio Kasagami. Careful-Patient Mover Used for Patient Transfer in Hospital, IEEE/ICME International Conference on Complex Medical Engineering, 2007(5): 20-26.

DOI: 10.1109/iccme.2007.4381684

Google Scholar

[3] Wang TM,Wei J,Liu D,et al. An internet robot assistant teleneuro surgery system case [A] / Proceedings of IEEE/RSJ International Conference on Intelligent Robots and Systems [C]. Beijing : IEEE, 2006, 2845-2849.

Google Scholar

[4] Proc. I Mech E, Part H J, Davies B. A review of robotics in surgery[J]. Engineering in Medicine, 2000, 214(H1)129-140.

Google Scholar

[5] Wang Dongxing. Based on AT89S52 digital blood pressure monitor [J]. The design and implementation of intelligent computer and applications, 2012, 3 (3); 84-86.

Google Scholar

[6] Yang Jian , Zhou Mingli . POCT blood glucose meter and blood glucose automatic biochemical analyzer comparative analysis of test results [J] State Journal of Laboratory Medicine , 2013, 34 ( 24 ) ; . 3396-3397.

Google Scholar

[7] He Xianzhao Long Xiwen, Ma Suhu etc. 4. Based on the research of acceleration of the walking motion model [J]. Mechanical and electrical engineering, 2011, 28 (1); 42-46.

Google Scholar

[8] Wang Junli Zhang Bing, Jia Liya etc. 4. Four kinds of motion sensors measuring the effectiveness of physical activity energy consumption study [J]. Journal of tianjin sports college, 2012, 27 (5); 427-431.

Google Scholar