Image Processing and Analysis System for Corneal Endothelial Cell Based on LabVIEW and MATLAB

Article Preview

Abstract:

To process corneal endothelial cell image quickly and efficiently, observe the corneal endothelial cell form and relevant calculation and analysis. This system adopts mixed programming of LabVIEW and MATLAB, to have image processing and analysis of the corneal endothelial cell. Use LabVIEW to design operation and display interface, and send the images collected to MATLAB for complex arithmetical operation, then put out data in LabVIEW. The experiment indicates the system has the advantage of intuitive interface, convenient operation, and quick arithmetic, has the practical reference value.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

3777-3781

Citation:

Online since:

November 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] J. Hu, Y.Z. Ye, L.N. Liu and Z.H. Cai: Cells morphology, Vol. 20(2012) No. 1, p.1.

Google Scholar

[2] L. Ventura, C.A.C. Caetano, and S.J.F. Sousa: A Corneal Endothelium Cell Analyzer for Slit Lamps, Vol. 21(2002) No. 6, p.92.

DOI: 10.1109/memb.2002.1175144

Google Scholar

[3] T.D. Zhang, A.J. Shih and E. Levin: Annals of the CIRP, Vol. 43 (1994) No. 3, p.305.

Google Scholar

[4] Q. Ma, M. Zhang and Z.X. Huang: Analysis and its clinical significance of normal corneal endothelial cells, Vol. 17(1999) No. 2, p.123.

Google Scholar

[5] F.Y. Li, X.P. Tan, C.Q. Yang, M.M. Zhou and S.Z. Liu. The density and morphological change rule of Normal corneal endothelial cell, Vol. 19(2001) No. 2, p.133.

Google Scholar

[6] Q. You, X.H. Song and Q. Xu. Analysis and clinical significance of diabetic cataract preoperative corneal endothelial cell. Beijing Medical Journal, Vol. 29(2007) No. 10, p.599.

Google Scholar

[7] J.P. Zhao. The nursing experience of checking corneal endothelial cells, Vol. 42(2013) No. 6, p.111.

Google Scholar

[8] N. Zhang: The research of several key technologies in image analyzer system. (MS. D, Sichuan University, China 2005), p.1.

Google Scholar

[9] Y. Chen, Y.J. Zeng and L. Fan: The research of corneal endothelial cells image automatic check system, Vol. 50(1998) No. 18, p.40.

Google Scholar

[10] X. Liu and P. Zhu: Research of the reliability of the application of simplified cells software in corneal endothelial cell image quantitative analysis, Vol. 16(2007) No. 6, p.422.

Google Scholar

[11] S.S. Xiao, S.F. Fan, X.B. Li and P.D. Jiang: The development and application of image analysis system about a single living cell, Vol. 35(2002) No. 3, p.309.

Google Scholar

[12] S.R. Zhu, F.Y. Kang, G.Z. Li, Q.X. Li and G.R. Li: Normal corneal endothelial cell image analysis by the computer, Vol. 21( 1999) No. 1, p.28.

Google Scholar

[13] F. Li: Image processing technology to one tube parts defects based on LabVIEW and Matlab, Vol. 31( 2012) No. 10, p.83.

Google Scholar

[14] Z.H. Lin, L.L. Song and Y.Q. Huang: Electronic speckle interference image processing system based on LabVIEW, Vol. 52(2013) No. 1, p.43.

Google Scholar

[15] X.G. Liang, Y.C. Zhang and T. Hong: The mixed programming of the LabVIEW and Matlab, Vol. 22(2009) No. 9, p.71.

Google Scholar

[16] Y.P. Zhang: Application in modern photometric image processing based on the LabVIEW and Matlab. (MS. D, Nanjing University of Aeronautics and Astronautics, China 2009), p.47.

Google Scholar

[17] L.N. Wei, S.Z. Guo: Ophthalmology, Vol. 5(1996) No. 3, p.167.

Google Scholar

[18] X.M. Wu, C.M. Guo, Y.S. Wang and X.G. Zhang: The change of normal corneal endothelium cell with aging, Vol. 18(2010) No. 6, p.481.

Google Scholar