A Multi-Objective Assessment for Primary Frequency of Generator

Article Preview

Abstract:

The ability of the generator unit response frequency change is the key issue of assessing primary frequency regulation. Meanwhile, the setting of speed regulating system parameter greatly affects primary frequency performance of generators. Therefore, this paper proposes a comprehensive evaluation system, which can comprehensively analyze and evaluate the ability of primary frequency regulation from various aspects. It combines speed regulating system parameter index with common evaluation index. In this part, the author puts forward a multi-objective assessment algorithm. Firstly, when generators experienced disturbances, collect the corresponding data of plant and system. Then the speed regulating system parameter is estimated by the actual accident of generator. Besides, the common evaluation index is calculated, including the contribution electric quantity, response time, delay time and the contribution ratio. Finally, the algorithm is applied to the actual hydro power units and thermal power units, and the results illustrate the feasibility and reliability of the algorithm.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

325-330

Citation:

Online since:

March 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] LI Miao, SUN Jianbo, LI Xiaoping, Online evaluation of primary frequency regulation based on WAMS, APPEEC 2012 Asia-Pacific Power and Engineering Conference.

DOI: 10.1109/appeec.2012.6307644

Google Scholar

[2] ZHANG Shuang, Overview of PMU-based Wide Area Measurement System for Power Network, Guangdong Electric Power, vol. 20, pp.26-29, Dec. (2007).

Google Scholar

[3] ZHENG Tao, DAI Zeimei, GAO Fuying, Estimate and evaluation of the control area PFR based on PMU, APAP 2011-Proceedings: 2011 International Conference on Advanced Power System Automation and Protection, v1, pp.643-647.

DOI: 10.1109/apap.2011.6180479

Google Scholar

[4] LI Duanchao, CHEN Zhongyuan, et al, Real-time measurement and reward method of the efficiency of generator unit primary frequency regulation, Automation of the Electric Power System, 2004, 28(2): 70-72.

Google Scholar

[5] YANG Jianhua, Research and development of assessment system of primary frequency regulation in Central China Power Grid, Automation of Electric Power System, 2008, 32(9): 96-99.

Google Scholar

[6] DAI Zemei, LIU Jiangang, ZHENG Tao, et al, Research on Unit Primary Frequency Regulation Evalution System Based On Phasor Measurement Unit, Power System Technology, 2010, 34 (Supplement 2): 396-399.

Google Scholar

[7] ZHENG Tao, Gao Fuying, On-line monitoring and computing of unit PFR characteristic parameter based on PMU, Automation of Electric Power Systems, v33, n 7, pp.57-61+71, June 10, (2009).

Google Scholar

[8] LIANG Zhengyu, Li Shanshan, Reseach on influence factor of primary frequency regulation performance for thermal power plant, Applied Mechanics and Materials, v 448-453, pp.2040-2044, (2014).

DOI: 10.4028/www.scientific.net/amm.448-453.2040

Google Scholar