Structural Response and Pounding of Andalas University Hospital Building Using New Indonesian Seismic Code SNI 1726-2012

Article Preview

Abstract:

Keywords: Earthquake, Internal Forces, Displacement, Response Spectrum Analysis, Time History Analysis, PoundingAbstract. Teaching Hospital is an educational facilitiy for students in the Faculty of Medicine and also as a health services for the general public. The hospital building must be built in accordance with earthquake-safe building standards, so that buildings are not damaged in an earthquake. Andalas University Hospital was built at Padang in 2014 which was designed using Indonesian Seismic Code SNI 03-1726-2002 with quakes zone 6. Since 2012, a new Seismic Code, SNI 1726-2012, was issued and all the buildings should be designed by using the new code. Therefore, the authors are interested in analyzing the structural response of the hospital building by using new seismic code SNI 1726-2012. The results, then, were compared with the responses of the structure which calculated by using SNI 03-1726-2002.The results of analysis show that the structural responses in the internal forces and displacement by using SNI 1726-2012 was higher than those using SNI 03-1726-2002. In this study, an analysis of potential Pounding was also conducted by using dynamic analysis Time History method. The analytical result shows that there is no pounding between adjacent buildings at Andalas University Hospital Buildings.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

274-282

Citation:

Online since:

July 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Earthquake Engineering Sectional Committee, Indian Standard Criteria For Earthquake Resistant Design of Structures (Fifth Revision), India. (2002).

Google Scholar

[2] Dhakal R, Structural Design For Earthquake Resistance: Past, Present and Future, University of Canterbury, Christchurch, New Zealand, (2011).

Google Scholar

[3] Julián C and Hugo HB., Analysis of the Earthquake-Resistant Design Approach for Buildings in Mexico. Engineering and Technology Research, Colombia. (2012).

Google Scholar

[4] National Standardization Agency of Indonesia, Design Method of Earthquake Resistance for Buildings and Other Structures, SNI 1726-2012, Jakarta, Indonesia. (2012).

Google Scholar

[5] National Standardization Agency of Indonesia, Design Standard of Earthquake Resistance for Buildings, SNI 03-1726-2002, Jakarta, Indonesia. (2002).

Google Scholar

[6] Andalas University, Construction Report of Unand Hospital Building, Padang, (2014).

Google Scholar

[7] CSI, ETABS ETABS Version 9. 7. 1, USA (2013).

Google Scholar

[8] Fulki, A., Analysis of Seismic Parameter, b Value and PGA in Papua, UIN Syarif Hidayatullah, Jakarta, Indonesia, (2011).

Google Scholar

[9] H. Kusuma, G., and Andriono, T., Design of Reinforced Concrete Frame Structure in Earthquake Zone, Erlangga, Jakarta, Indonesia (1993).

Google Scholar

[10] Shah, Hemal J, , Seismic Time History Analysis Of Building On Sloping Ground Cosidering Near/Far field Earthquake, International Journal of Engineering Research & Technology (IJERT) Vol. 3 Issue 3, India, 2014, pp.982-986.

Google Scholar