The Effect of Air Curtain on Controlling Contaminants in Wards

Article Preview

Abstract:

Controlling the concentration of contaminants in wards to prevent airborne infection is an important issue in hospital. The effect of supply airflow of down-feed air curtain, which locates between patients and doctors/nurses, is to separate wards into two spaces, one for patients and the other for doctors/nurses. The controlling effects of air curtain on contaminants emitted by patients are numerically simulated under different air arrangements. In a laboratory model, the smoke of burning Zang incense serves as the source of contaminants. Particles’ concentration of contaminants was tested with a laser particle counter at different sites whether the air curtain was running or not. Draughty feel on patients caused by supply airflow of air curtain was researched in this study. Results of the present study revealed that air curtain could control contaminants effectively, and the supply airflow did not make patients discomfort basically. Finally, the appropriate air outlet location and distance between air curtain and patients were suggested.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 433-440)

Pages:

1265-1270

Citation:

Online since:

January 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Xu Shijie, Fan Qiang. Replacement of hot air curtain with static pressure fan-coil and fresh air system. Refrigeration and Air-conditioning, 2005, 5(3): 90-92.

Google Scholar

[2] Xie Xiaoqiang, Luo Kai. Organizing analysis method of air curtain fitting for engineering device and testing. Journal of Chang'an University( Arch. & Envir. Science Edition), 2004, 21(3): 29-31.

Google Scholar

[3] Wang Haining, Zhang Hongjing. Test and application of air curtain in mine. Journal of China Coal Society, 2006, 31(5): 615-617.

Google Scholar

[4] Song Feng, Zhang Hanhong, Wen Yuqin, et al. Movable assembly air screen applied in clinical operation. China Journal of Nosocomiol, 200313(12): 1147-1148.

Google Scholar

[5] Zhou Ru, He Jiapeng, Xie Juan, et al. Numerical simulation and analysis of the air curtain for preventing smoke in subway station fire. China Safety Science Journal, 2006, 16(3): 27-30.

Google Scholar

[6] Huang Jengmin, Shi-Ming Tsao. The influence of air motion on bacteria removal in negative pressure isolation rooms. HVAC & R Research, 2005, 11(4): 563-585.

DOI: 10.1080/10789669.2005.10391155

Google Scholar

[7] Tao Wenquan. Numerical Heat Transfer. Xian: Xi'an Jiaotong University Press, Xian, (2001).

Google Scholar

[8] Ministry of Construction of the People's Republic of China. 2003. GB 50019-2003 Code for Design of Heating, Ventilating and Air Conditioning. Beijing: China Planning Press.

Google Scholar