The Study on Configuration and Setting of Relay Protection when Distributed Generation Accesses to Distribution Network

Article Preview

Abstract:

When distributed generation (DG) accesses to non-system bus , and the power capacity increases to a certain extent, it will cause malfunction of protective devices, as a result of which ,protective devices lose selectivity. This paper analyzes influence to relay protection of power system as a result of the access of DG, establishes a model of the access of DG, and proposes principles of reconfiguration of protection devices, and re-setting of relay protection when DG accesses to power system. This method provides a theoretical basis for designing of DG accessing to power system, reconfiguration of protection devices and re-setting of relay protection.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 433-440)

Pages:

1950-1956

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] M. Go and Q. Ai, Analysis on the Influence of Connecting Distributed Generation on the Relaying of Distribution System, Distribution & Utilization, Vol. 27, No. 1, Feb. 2010, pp.1-3, 37.

Google Scholar

[2] X.D. Yu, Y.H. Zhao and P. He, Effect of Distributed Generation on Relay Protection, Jilin Electric Power, Vol. 37, No. 4, Aug. 2009, pp.8-10.

Google Scholar

[3] X.M. Li and S.Q. Liu, Study and Countermeasures on Distributed Generation and its Impaction on Line Protection of Distribution Networks, High-Technology & Industrialization, No. 11, Nov. 2009, pp.80-83.

Google Scholar

[4] S. Liu, Distribution Network Protection with Distributed Generation, Doctoral Dissertation, Tianjin, Tianjin University, (2007).

Google Scholar

[5] J.Q. Cui, Q.Y. Meng, Y.F. Chen and B.Y. Xiong, Setting Calculation of Power System Protection and Security Automatic Equipment, China Water Power Press, Beijing, China, (1993).

Google Scholar

[6] B.H. Zhang and X.G. Yin, Power System Protective Relaying, China Electric Power Press, Beijing, China, (2005).

Google Scholar

[7] Jenkins, N., Allan, R., Crossley, P., Kirschen, D., Strbac, G., 2000, Embedded Generation, IEE.

Google Scholar

[8] Brahma,S. M, Girgis, A.A., 2002, IEEE PES Winter Meetinr, Vol. I, Microprocessor-Based Reclosing to Coordinate Fuse and Recloser in a System with High Penetration of Distributed Generation, 453-458.

DOI: 10.1109/pesw.2002.985041

Google Scholar

[9] K. Kauhaniemi, L. Kumnpulainen, Impact of distributed generation on the protection of distribution networks, in Proc et lEE Int. Conf. on Developments in Power System Protection 2004, vol. 1, pp.315-318, (2004).

DOI: 10.1049/cp:20040126

Google Scholar

[10] L. Kumpulainen, K. Kauhaniemni, P. Verho,. Vahamaki, New requirements for system protection caused by Distributed Generation, in Proc. 18h Int. Conf. On Electricity Distribution, 4pp, Turin, 6-9June (2005).

DOI: 10.1049/cp:20051183