Discussion on Operation Mode of Long Distances Gravity-Fed Pressure Diversion Project

Article Preview

Abstract:

The characteristics of long distance gravity-fed pressure water-conveying projects are long pipe length, huge changes in rise and down of pipeline arrangement, and complex hydraulic conditions. It is the water hammer that mainly influences the safe operation of such projects. Based on a real long distance gravity-fed pressure water conveying pipeline system, fluid transients processes under different operation modes were analyzed by using the method of characteristics. The pipeline longitudinal arrangement is high in two ends and low in the middle part. The research puts forward that for such pipeline arrangement using valve set in the midway of the pipeline to control the system is evidently better than that of valve at the downstream end of pipeline. In this way, pipeline working pressure can be effectively reduced, in turn, the pipe pressure grade can be decreased and the investment of the project can be reduced.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 433-440)

Pages:

7125-7130

Citation:

Online since:

January 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Sun Wangong. Research on pressure reducing methods of long distance water diversion pipeline system. Water Resources Planning and Design[J ], 2003. 3: 57-58.

Google Scholar

[2] Zhong Denghua, Liu Jianmin, Xiong Kaizhi. Research on Simulating Optimization of Long-distance Complex Water Conveyance Systems. Engineering Science[J ] . 2005, 7(10): 60-63.

Google Scholar

[3] Yang xiaofeng. Design of pressure control along the way of long distance water diversion project. Hydraulic Science and Technology, [J ]. 2007, (4): 31-32.

Google Scholar

[4] Wylie E. B., Streeter V. L., and Suo Lisheng, Fluid Transient in System [M]. Prentice2Hall, Englewood Cliffs, (1993).

Google Scholar

[5] Code for design of outdoor water supply engineering. (GB50013-2006)[M]. Beijing: China Planning Press, (2006).

Google Scholar

[6] Test methods of concrete pipes for water transmission. (GB/T15345-2003). [M]. Beijing: China Planning Press, (2003).

Google Scholar

[7] BI Xiao-jian, ZHAO Xiu-hong, YANG Bao-kui, ZHU Man-lin. Optimum Design of Pressured Gravity Water Transportation in Long Distance. Journal of Water Resources and Architectural Engineering, [J]. 2007, (1): 28-30.

Google Scholar

[8] Wang Tao, Zhu Manlin, Zhang Yanhe. Optimal Design of Long Distance Pressure Water Delivery Pipeline System. Third 2008 International Conference on Convergence and Hybrid Information Technology, Vol 1, Proceedings, 1013-1017, South Korea, Nov 11-13, (2008).

DOI: 10.1109/iccit.2008.170

Google Scholar