Temperature Calculation on Phase Lead Connecting Structures of 1100MW Generator Stator Parallel Rings
Abstract:
The temperature rise of generator components has a great impact on operation performance for large turbine generator. In this paper, applying the general FE calculation software-ANSYS, with a sequential electromagnetic-thermal field coupling calculation method, temperature calculation on phase lead connecting structures of 1100MW nuclear power turbine generator parallel rings is presented. The calculation results could offer a basic analysis to optimize the design of the generator.
Info:
Periodical:
Pages:
7131-7137
Citation:
Online since:
January 2012
Authors:
Price:
Сopyright:
© 2012 Trans Tech Publications Ltd. All Rights Reserved