An Experimental Study on Ultimate Behaviors of Double Shear Bolted Connections with Ferritic Stainless Steel

Article Preview

Abstract:

Based on the existing test results of single shear bolted connection fabricated with cold-formed ferritic stainless steel, in this study, the experiment for double shear bolted connections with bolt arrangements(1×2, 2×2) and end distance parallel to the loading direction as main variables has been performed. Specimens were planed with a constant dimension of edge distance perpendicular to the loading direction, bolt diameter, pitch and gauge. Ultimate strength and fracture mode obtained from test results were compared with those predicted by current American and Japan design codes such as AISI and AIJ.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

976-979

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Jin-seong LIM, Tae-soo KIM, Seung-hun KIM : Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), DOI : 10. 1631(2012).

Google Scholar

[2] American Iron and Steel Institute (AISI) : North American Specification for the Design of Cold-Formed Steel Structural Members, AISI S100-07(2007).

Google Scholar

[3] Architectural Institute of Japan (AIJ) : Recommendation for Limit State Design of Steel Structures. AIJ(2002).

Google Scholar

[4] Japan Industrial Standards(JIS) : Method of tensile test for metallic materials, Japan Industrial Standards, JIS Z 2241(2010).

Google Scholar

[5] Japan Industrial Standards(JIS) : Stainless steel for building structure, Japan Industrial Standards, JIS GZ 4321(2010).

Google Scholar