Investigation of Mixing Flow Process Using PIV and PLIF Techniques

Article Preview

Abstract:

A coolant mixing investigation in a head of a half-size model of VVER-440 fuel assembly (simulator) has been performed at KFKI. The PIV and PLIF measurements have been done under a selected list of power distribution options, flow rates and powers. The experiments were focused on obtaining a data for investigating the trends in temperature difference between the value registered by a thermocouple and that obtained using PLIF technique. The coolant temperature distribution has been measured in many positions along the coolant trajectory and where coolant flow leaves the rod bundle and in the cross section location of thermocouple, thus the dynamics of effect of mixing process is also declared. PIV and LPIF results show their ability to verify the primary results of CFD calculations.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 816-817)

Pages:

1054-1058

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Rita F., Pedro C., Thermal-hydraulic Behavior of Electrically Heated Rod during a Critical Heat Flux Transient, J. Braz. Soc. Mech. Sci. vol. 22 no. 4 Rio de Janeiro,  (2000) http: /dx. doi. org/10. 1590/S0100-73862000000400010.

DOI: 10.1590/s0100-73862000000400010

Google Scholar

[2] Rehme, K., Pressure drop correlations for fuel element spacers", Nuclear Technology, Vol. 17 (1973), pp.15-23.

DOI: 10.13182/nt73-a31250

Google Scholar

[3] Chun, T. H., Oh, D. S., A pressure drop model for spacer grids with and without flow mixing vanes, Journal of Nuclear Science and Technology, Vol. 35(1998), pp.508-510.

DOI: 10.1080/18811248.1998.9733899

Google Scholar

[4] Shen, Y. F., et al. An investigation of cross-flow mixing effect caused by grid spacer with mixing blates in a rod bundle, Nuclear Engineering and Design, Vol. 125(1991), pp.111-119.

DOI: 10.1016/0029-5493(91)90071-o

Google Scholar

[5] Holloway, M. V., et al. The effect of support grid features on local, single-phase heat transfer measurements in rod bundles, Journal of Heat Transfer, Vol. 126 (2004), pp.43-53.

DOI: 10.1115/1.1643091

Google Scholar

[6] Karoutas, Z., et al., 3D Flow analyses for design of Nuclear Fuel Spacer, Proceedings of the 7th International Meeting on Nuclear Reactor Thermal-hydraulics NURETH-7, New York, USA(1995), pp.3153-3174.

Google Scholar

[7] Imaizumi, M., et al, Development of CFD method to evaluate 3D flow characteristics for PWR fuel assembly, Transactions of the 13th International Conference on Structural Mechanics in Reactor Technology SMIRT 13, Porto Alegre, Brazil(1995).

Google Scholar

[8] Ikeda, K., Hoshi, M., Development of Mitsubishi high thermal performance grid, JSME International Journal, series B, Vol. 45 (2002), pp.586-591.

DOI: 10.1299/jsmeb.45.586

Google Scholar

[9] Ikeno T., Kajishima, T., Decay of swirling turbulent flow in rod-bundle. Journal of Fluid Science and Technology, Vol. 1 (2006), pp.36-47.

DOI: 10.1299/jfst.1.36

Google Scholar

[10] Caraghiaur, D., Anglart, H., Measurements and CFD predictions of velocity, turbulence intensityand pressure development in BWR fuel rod assembly with spacers. Proceedings of the 12th International Meeting on Nuclear Reactor Thermal Hydraulics (NURETH12), Pittsburgh, Penn. (2007).

Google Scholar