Study the Effect of Fluid Medium toward Synthetic Cancellous Bone Structure

Article Preview

Abstract:

During daily activities, trabecular bone need to bear certain amount of load which also leads to movement of the bone marrow within the structure. The flow of the bone marrow within the trabecular bone structure cause the shear stress which affect the nutrient transport, the properties of the bone and also the bone fatigue life. The aim of this paper is to simulate the trabecular structure using FSI approach in order to study the effect of the fluid flow to the structure. In this study, idealized model with 50% of porosity was used in the simulation and 1mm displacement applied on top of the model. Three different types of analysis were used in order to differentiate between CFD, CSM and FSI results. The results showed significant value between these analyses was concluded that FSI approaches is the best to mimic the real body condition.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

335-339

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Schnitzler, C.M. and J. Mesquita, Bone Marrow Composition and Bone Microarchitecture and Turnover in Blacks and Whites. Journal of Bone and Mineral Research, 1998. 13(8): pp.1300-1307.

DOI: 10.1359/jbmr.1998.13.8.1300

Google Scholar

[2] Piney, A., The Anatomy of the Bone Marrow: With Special Reference to the Distribution of the Red Marrow. The British Medical Journal, 1922. 2(3226): pp.792-795.

Google Scholar

[3] Raja Izaham, R.M.A., et al., Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy. Injury, 2012. 43(6): pp.898-902.

DOI: 10.1016/j.injury.2011.12.006

Google Scholar

[4] Kadir, M., A. Syahrom, and A. Öchsner, Finite element analysis of idealised unit cell cancellous structure based on morphological indices of cancellous bone. Medical and Biological Engineering and Computing, 2010. 48(5): pp.497-505.

DOI: 10.1007/s11517-010-0593-2

Google Scholar

[5] Abdul Kadir, M.R. and N. Kamsah, Interface micromotion of cementless hip stems in simulated hip arthroplasty. American Journal of Applied Sciences, 2009. 6(9): pp.1682-1689.

DOI: 10.3844/ajassp.2009.1682.1689

Google Scholar

[6] Syahrom, A., et al., Mechanical and microarchitectural analyses of cancellous bone through experiment and computer simulation. Medical & Biological Engineering & Computing, 2011. 49(12): pp.1393-1403.

DOI: 10.1007/s11517-011-0833-0

Google Scholar

[7] Syahrom, A., et al., Permeability studies of artificial and natural cancellous bone structures. Medical Engineering & Physics, 2012(0).

Google Scholar

[8] Lee Waite and Jerry Fine, Applied Biofluid Mechanics. 2007, New York, Chicago, San Francisco, Lisbon, London, Madrid, Mexico City, Milan, New Delhi, San Juan, Seoul, Singapore, Sydney, Toronto: The McGraw-Hill Companies, Inc.

Google Scholar

[9] Grimm, M.J. and J.L. Williams, Measurements of permeability in human calcaneal trabecular bone. Journal of Biomechanics, 1997. 30(7): pp.743-745.

DOI: 10.1016/s0021-9290(97)00016-x

Google Scholar

[10] Nauman, E.A., K.E. Fong, and T.M. Keaveny, Dependence of Intertrabecular Permeability on Flow Direction and Anatomic Site. Annals of Biomedical Engineering, 1999. 27(4): pp.517-524.

DOI: 10.1114/1.195

Google Scholar

[11] Kohles, S.S., et al., Direct perfusion measurements of cancellous bone anisotropic permeability. Journal of Biomechanics, 2001. 34(9): pp.1197-1202.

DOI: 10.1016/s0021-9290(01)00082-3

Google Scholar

[12] Baroud, G., et al., Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration. Journal of Biomechanics, 2004. 37(2): pp.189-196.

DOI: 10.1016/s0021-9290(03)00246-x

Google Scholar