A Study on the Hard Wearing UV Treated Photopolymer Printing Plate for Articular Replacement/Arthroplasty (Biomedical)

Article Preview

Abstract:

Nowadays the usage of polymer on articular replacement (arthropasty) is common because of their known usage in orthopedic surgery and biocompatibility. The polymeric material such as polyethylene and polyacetal are common materials used in surgical repair of joint due to the arthritic or dysfunctional joint surface. The surgical repair is done by replacing the damage part with something better or remodeling or realigning the joint by osteotomy procedures. In this case, for both hip and knee replacement, chrome-cobalt and polymer are commonly used. According to Jennifer Brown, the cost for knee replacement is approximate to USD$15,000 per procedure with the estimation of total knee replacement is 600,000 annually in United States. Currently, the aggregate of annual cost for total knee replacement is about USD$9 billion. The usage of chrome-cobalt and polymer is very common and save but the cost is very expensive. The other disadvantage is it usually last only for 10 years for hip and knee replacement.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

362-365

Citation:

Online since:

March 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] K. L. Edwards, Towards an improved development process for new hip prostheses, Mater. Des., vol. 29, no. 2, p.558–561, Jan. (2008).

Google Scholar

[2] M. Bahraminasab and A. Jahan, Material selection for femoral component of total knee replacement using comprehensive VIKOR, Mater. Des., vol. 32, no. 8–9, p.4471–4477, Sep. (2011).

DOI: 10.1016/j.matdes.2011.03.046

Google Scholar

[3] N. R. Patel and P. P. Gohil, A Review on Biomaterials : Scope , Applications & Human Anatomy Significance, vol. 2, no. 4, (2012).

Google Scholar

[4] G. Blunn, E. M. B. Preva, L. Costa, J. Fisher, And M. A. R. Freeman, Ultra High Molecular-Weight Polyethylene (Uhmwpe) In Total Knee Replacement: Fabrication, Sterilisation And Wear G. Blunn, E. M. Brach Del Preva, L. Costa, J. Fisher, M. A. R. Freeman, Pp. 946–949, (2002).

DOI: 10.1302/0301-620x.84b7.0840946

Google Scholar

[5] B. Mckelvogue and F. Mentor, Improvements to UHMWPE A Scientific Review, (2010).

Google Scholar

[6] L. I. U. Ji, Z. H. U. Yuan-yuan, W. Qing-liang, and G. E. Shi-rong, Biotribological behavior of ultra high molecular weight polyethylene composit巳s containing bovine bone hydroxyapatite, no. April, (2008).

Google Scholar

[7] H. Haider, J. N. Weisenburger, S. M. Kurtz, C. M. Rimnac, J. Freedman, D. W. Schroeder, and K. L. Garvin, Does vitamin E-stabilized ultrahigh-molecular-weight polyethylene address concerns of cross-linked polyethylene in total knee arthroplasty?, J. Arthroplasty, vol. 27, no. 3, p.461–9, Mar. (2012).

DOI: 10.1016/j.arth.2011.03.024

Google Scholar

[8] M. S. Yusof, Printing Fine Solid Lines in Flexographic Printing Process, College of Engineering Swansea University, (2011).

Google Scholar