Experimental Study on Detection Method of Micro-Fluidic Chip

Article Preview

Abstract:

A fluorescent markers based two-dimensional parallel detection technique of Micro-fluidic chip is studied. In a special designed fluid field of test sample, excite fluorescence of micro-spheres probe by pulse-laser and employ high sensitivity CCD to catch it. The entire information from micro-fluidic chip can be obtained via a computer post-processing of the caught signal of fluorescence. Analyzed the probe flow state and fluorescence signal intensity of detection program. Established the expressions of fluorescence signal intensity and the parameters of detection system. Validation experiments indicate that this detection method has the advantages of rapid, accurate and high sensitivity.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

405-409

Citation:

Online since:

June 2014

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Fodor S, Rava R, Huang X, et al. Multiplexed Biochemical Assays with Biological Chips [J]. Nature, 1993, 364(6437): 555-556.

DOI: 10.1038/364555a0

Google Scholar

[2] Schena M, Shalon D, Davis R, et al. Quantitative Monitoring of Gene Expression Patterns with a ComplementaryDNA Microarray [J]. Science, 1995, 270(5235): 467-470.

DOI: 10.1126/science.270.5235.467

Google Scholar

[3] Ye R, Wang T, Bedzyk L, et al. Applications of DNA Microarrays in Microbial Systems [J]. J. Microbiol. Meth., 2001, 47 (3): 257-272.

Google Scholar

[4] Dhiman N, Blnilla R, O'kane J D, et al. Gene Expression Microarrays: a 21st Century Tool for Directed Vaccine Design[J]. Vaccine, 2002, 20 (1-2): 22-30.

DOI: 10.1016/s0264-410x(01)00319-x

Google Scholar

[5] Sprio A, Lowe M, Brown D. A bead-based method for multiplexed identification and quantitation of DNA sequences using flow cytometry[J]. Applied and Environmental Microbiology, 2000 , 66(10): 4256-4265.

DOI: 10.1128/aem.66.10.4258-4265.2000

Google Scholar

[6] Li Yang et al. Badge, beads array for the detection of gene expression, a high-throughput diagnostic bioassay[J]. Genome Research, 2001, 11(11): 1888-1898.

DOI: 10.1101/gr.190901

Google Scholar

[7] Nolan J, Sklar L. Suspension array technology: evolution of the flat-array paradigm[J]. Trends in Biotechnology, 2002, 20(1): 9-12.

DOI: 10.1016/s0167-7799(01)01844-3

Google Scholar

[8] Pawley J. Hand book of confocal Microsphere. 1994, NY, Plenum Press. chapter 16.

Google Scholar