An On-Line Monitoring Method of Interharmonics Based on ANF and Interpolated FFT

Article Preview

Abstract:

To detect interharmonics whose amplitudes are often small, a detection method based on ANF and interpolated FFT is proposed. In the method, the parallel structure of the ANF (adaptive notch filter) is firstly used to detect the fundamental and harmonic components, in which the fundamental frequency signal with high amplitude is detected with the main ANF and then the measured base frequency is output to sub-parallel ANF structure so as to extract the harmonic components. Then a separated interpolated fast Fourier transformation (FFT) analysis of interharmonic components will be effectively completed without the influence of the fundamental and harmonic components. A detection platform based on the proposed method is implemented in LabVIEW. The results of simulation and experiments show the effectiveness of the method.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 986-987)

Pages:

1453-1456

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Testa A, Akram M F, Burch R, et al. Interharmonics: Theory and modeling[J]. IEEE Transactions on Power Delivery, 2007, 22(4): 2335-2348.

Google Scholar

[2] Francesco D, Roberto L, Adolfo S, et al.On the interharmonic components generated by adjustable speed drives[J]. IEEE Transactions on Power Delivery, 2005, 20(4): 2535-2543.

DOI: 10.1109/tpwrd.2005.852313

Google Scholar

[3] Karimi Ghartemani M, RezaIravani M. Measurement of harmonics/interharmonics of time-varying frequencies[J]. IEEE Trans on Power Delivery, 2005, 20(1): 23-31.

DOI: 10.1109/tpwrd.2004.837674

Google Scholar

[4] Mojiri M, Karimi-Gharteman M, Bakhshai A. Processing of harmonics and interharmonics using an adaptive notch filter[J]. IEEE Trans on Power Delivery, 2010, 25(2): 534-542.

DOI: 10.1109/tpwrd.2009.2036624

Google Scholar

[5] Qian Hao, Zhao Rongxiang, Chen Tong. Interharmonics analysis based on interpolating windowed FFT algorithm[J]. IEEE Trans on Power Delivery, 2007, 22(2): 1064-1069.

DOI: 10.1109/tpwrd.2007.893187

Google Scholar

[6] Chang G W, Chen C I, Liu Y J, et al. Measuring power system harmonics and Interharmonics by an improved fast Fourier transform-based algorithm[J]. IET Generation, Transmission& Distribution, 2008, 2(2): 192–201.

DOI: 10.1049/iet-gtd:20070205

Google Scholar

[7] MA Bing-wei, LIU Hui-jin, ZHOU Li, et al. An improved algorithm of interharmonic spectral estimation based on AR model[J]. Proceedings of the CSEE, 2005, 25(15): 79-83.

Google Scholar

[8] Ding Yifeng, Cheng Haozhong, Lü Ganyun, et al. Spectrum estimation of farmonics and interharmonics based on prony algorithm[J]. Transactions of China Electrotechnical Society, 2005, 20(10): 94-97.

Google Scholar

[9] Guo Cheng, Li Qunzhan, He Jianmin, et al. Segmentation prony algorithm on harmonics and inter-harmonics detection of power networks[J]. Power System Technology, 2010, 34(3): 21-25.

Google Scholar

[10] WANG Zhi-qun, ZHU Shou-zhen, ZHOU Shuang-xi.Inter-harmonics estimation by pisarenko harmonic decomposition method[J]. Power System Technology, 2004, 28(15): 72-77.

Google Scholar