Analysis of Arc Suppression Coil Accident in Fushun Zhongzhai 66kV Substation

Article Preview

Abstract:

Through the analysis of 66kV arc suppression coil smoke accident in Fushun Zhong Zhai 220kV substation,scientifically pointed out that the accident was due to leave hidden trouble in the process of design and manufacture of cause.This paper introduces the working principle of arc suppression coil and use value, and cites several reasons can cause arc suppression coil accidents.This paper introduces in detail the whole process of hoisting core checks after the accident in Liao Ning Yongtai Transformer Manufacturing Co., Ltd,and carefully check the chromatography test data and the operation report before and after the accident, proveing the results of the analysis of the accident is correct.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 986-987)

Pages:

215-218

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Chen Jiabin. Substation operation and management techniques. China power press, 2004.

Google Scholar

[2] Lei Yugui. Substation maintenance. China Waterpower Press, (2006).

Google Scholar

[3] The North Star power network. Function and selection of arc suppression coil. (2008).

Google Scholar

[4] State Grid Corporation. 10 ~ 66 kV arc suppression coil plant operation specification. (2005).

Google Scholar

[5] State Grid Corporation. 10 ~ 66 kV arc suppression coil device technical supervision regulation.

Google Scholar