Analysis of Key Factors Affecting Double-Circuit Transmission Lines Parameters and Transposition Schemes

Article Preview

Abstract:

Double-circuit transmission lines parameters symmetry would affect the normal operation of the transmission lines and relay protection actions directly. This paper analyzes the impacts of three different phase sequence arrangements on parameters symmetry of conventional un-transposed double-circuit lines, and requirements can be met by the parameters symmetry for double-circuit transmission lines with different types and different length. Took practical engineering requirements into consideration, a simple and admissible suggestion on phase sequence arrangements and the transposition modes is given. The research results provide useful guidance and reference for future designs of double-circuit lines, especially for the compact one.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 986-987)

Pages:

223-226

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Huang Weigang. Study on conductor configuration of 500 kV chang-fang compact line. IEEE Trans on PWRD,18(3):1002-1008,(2003).

DOI: 10.1109/tpwrd.2003.813828

Google Scholar

[2] Wenzel T., Leibfried T. Vacuum Circuit Breakers in Flexible AC Transmission Systems. IEEE Transactions on Power Delivery, 27(1): 236-244, (2012).

DOI: 10.1109/tpwrd.2011.2172820

Google Scholar

[3] Faruque M. O., Yuyan Zhang; Dinavahi V. Detailed Modeling of CIGRE HVDC Benchmark System Using PSCAD/EMTDC and PSB/SIMULINK. IEEE Transactions on Power Delivery, 21(1): 378-387, (2006).

DOI: 10.1109/tpwrd.2005.852376

Google Scholar

[4] Yining, Z., Jiale S. Phaselet-based Current Differential Protection Scheme Based on Transient Capacitive Current IET Compensation. Generation, Transmission & Distribution, 2(4): 469-477, (2008).

DOI: 10.1049/iet-gtd:20070494

Google Scholar

[5] SUN Qiu-qin, WANG Guan, LI Qing-min, ZHANG Yu-jun, XU Di, ZOU Zhen-yu. Calculation and Analysis of the Coupling Effects of the UHV Double - circuit Transmission Lines. High Voltage Engineering. (2010).

Google Scholar

[6] ZHANG Yao-qiang,ZHANG Tian-guang,WANG Yu-ping,LI Ben-liang,HU Xuan. Research on Electric Unbalance Degree and Conductor Transposition of 1000 kV Double-Circuit Transmission Line on the Same Tower. Power System Technology. (2011).

Google Scholar

[7] BAN Lian-geng,WANG Xiao-gang,BAI Hong-kun,LIN Ji-ming,MAO Yu-bin,XIANG Zu-tao,WANG Xiao-tong,ZHENG Bin,HAN Bin,LI Xiao-ming. Simulative Analysis of Induced Voltages and Currents Among Multi Circuit 220 kV and 500 kV Transmission Lines on Same Tower. Power System Technology. (2012).

DOI: 10.1109/powercon.2010.5666024

Google Scholar