Study of the Life of Partial Removable Denture Manufactured by PMMA Reinforced with Nano TiO2

Article Preview

Abstract:

In this study the effect of adding different weight ratio (0.5, 1, 1.5, 2)% of TiO2 nanoparticles powder extend the life of removable partial dentures made by PMMA was studied.The PMMA has low mechanical properties. Then the life is relatively short. After adding these different weight ratios, it found that the highest ultimate compressive stress was at the weight ratio 1.5% . The chewing force measured using a special sensors F-scan, which represents a mat of micro-sensors.When the value of the chewing pressure was 312 kPa. To measure the life of partial dentures, a special device was manufactured that applied a force that simulated the force generated during chewing . It measured by the f-scan sensor, and the best life of 1.5% TiO2 was added by weight. The lifetime of dentures increased by about 80% after adding 1.5 wt% of TiO2 nanoparticles.

You might also be interested in these eBooks

Info:

Pages:

3-12

Citation:

Online since:

August 2022

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2022 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Andreas Boger, Adrian Bisig, Marc Bohner, Paul Heini, Erich Schneider, Variation of the mechanical properties of PMMA to suit osteoporotic cancellous bone, J. Biomater Sci Polym. 19(9)(2008)1125-42.

DOI: 10.1163/156856208785540154

Google Scholar

[2] Beck S, Boger A., Evaluation of the particle release of porous PMMA cements during curing, J. Acta Biomater. 5(7)(2009) 2503-7.

DOI: 10.1016/j.actbio.2009.04.002

Google Scholar

[3] Ameer A. Kadhim, Muhannad Al-Waily, Zaman Abud Almalik Abud Ali, Muhsin J. Jweeg, Kadhim K. Resan, Improvement Fatigue Life and Strength of Isotropic Hyper Composite Materials by Reinforcement with Different Powder Materials, J. Mechanical & Mechatronics Engineering IJMME-IJENS, 18(2018) 77-86.

Google Scholar

[4] Muhsin J. Jweeg, Muhannad Al-Waily, Ahmed K. Muhammad, Kadhim K. Resan, Effects of Temperature on the Characterisation of a New Design for a Non-Articulated Prosthetic Foot, (IOP Conference Series: Materials Science and Engineering, 2ndInternational Conference on Engineering Sciences, Kerbala, Iraq, 433(2018)1-8.

DOI: 10.1088/1757-899x/433/1/012064

Google Scholar

[5] Marwah Mohammed Abdulridha, Nasreen Dakel Fahad, Muhannad Al-Waily, Kadhim K. Resan 2018 Rubber Creep Behavior Investigation with Multi Wall Tube Carbon Nano Particle Material Effect (International Journal of Mechanical Engineering and Technology (IJMET)) Vol. 09, No. 12, pp.729-746.

Google Scholar

[6] Saif M. Abbas, Kadhim K. Resan, Ahmed K. Muhammad, Muhannad Al-Waily 2018 Mechanical and Fatigue Behaviors of Prosthetic for Partial Foot Amputation with Various Composite Materials Types Effect(International Journal of Mechanical Engineering and Technology (IJMET)) Vol. 09, No. 09, p.383–394.

Google Scholar

[7] Muhsin J. Jweeg, Kadhim K. Resan, Mustafa Tariq Ismail, Study of Creep-Fatigue Interaction in a Prosthetic Socket Below Knee, (ASME International Mechanical Engineering Congress and Exposition), IMECE 85240(2012)1105-1110.

DOI: 10.1115/imece2012-85240

Google Scholar

[8] Muhsin J. Jweeg, Muhannad Al-Waily, Alaa Abdulzahra Deli, Theoretical and Numerical Investigation of Buckling of Orthotropic Hyper Composite Plates, J. Mechanical & Mechatronics Engineering, IJMME-IJENS, 15(2018)1-12.

Google Scholar

[9] A.M. Takhakh, F.M. Kadhim, and J.S. Chiad, Vibration Analysis and Measurement in Knee Ankle Foot Orthosis for Both Metal and Plastic KAFO Type,, ASME 2013 International Mechanical Engineering Congress and Exposition IMECE 64641 (2013)1-11.

DOI: 10.1115/imece2013-64641

Google Scholar

[10] S. Heloisa, Á. Gisseli, C. Geraldo, R. Elimário, F. Aline, F. Amanda, D. Sergio, Biomechanical Behavior of Tooth-Supported Fixed Partial Prostheses Components with Two Different Infrastructures, J. Metal and Polyether Ether Ketone (Peek), Oral Health and Dental Management, 18(2019)1-5.

DOI: 10.35248/2247-2452.19.18.1074

Google Scholar

[11] S.M. Abbas, K.K. Resan, A.K. Muhammad, and M. Al-Waily, Mechanical and Fatigue Behaviors of Prosthetic for Partial Foot Amputation with Various Composite Materials Types Effect, J. Mechanical Engineering and Technology (IJMET), 09(2018)383–394.

Google Scholar

[12] L.E. Yousif, K.K. Resan, and R.M. Fenjan, Temperature Effect on Mechanical Characteristics of A New Design Prosthetic Foot, J. Mechanical Engineering and Technology (IJMET), 09(2018) 1431-1447.

Google Scholar

[13] Z.Y. Hussien, K.K. Resan, Effects of Ultraviolet Radiation with and without Heat, on the Fatigue Behavior of Below-Knee Prosthetic Sockets, J. Mechanical and Production Engineering Research and Development (IJMPERD), 7(2017) , 641-652.

DOI: 10.24247/ijmperddec201772

Google Scholar

[14] Besinis, A, Hadi, S.D.,Le H.R., Tredwin, C., Handy, R.D., Antibacterial activity and biofilm inhibition by surface modified titanium alloy medical implants following application of silver titanium dioxide and hydroxyapatite nanocoatings, J. Nanotoxicology, 11(2017)327–338.

DOI: 10.1080/17435390.2017.1299890

Google Scholar

[15] E.A. Abbod, M. Al-Waily, Z.M.R. Al-Hadrayi, K.K. Resan, S.M. Abbas, Numerical and Experimental Analysis to Predict Life of Removable Partial Denture, IOP Conference Series: Materials Science and Engineering, 1st International Conference on Engineering and Advanced Technology, Egypt, 870(2020)1-9.

DOI: 10.1088/1757-899x/870/1/012149

Google Scholar

[16] Muhannad Al-Waily, Iman Q. Al Saffar, Suhair G. Hussein, Mohsin Abdullah AlShammari, Life Enhancement of Partial Removable Denture made by Biomaterials Reinforced by Graphene Nanoplates and Hydroxyapatite with the Aid of Artificial Neural Network, J. Mechanical Engineering Research and Developments, 43(2020) 269-285.

Google Scholar

[17] Ali Alrahlah, H. Fouad, Mohamed Hashem, Abdurahman A. Niazy, Abdulhakim AlBadah, Titanium Oxide (TiO2)/Polymethylmethacrylate (PMMA) Denture Base Nanocomposites: Mechanical, Viscoelastic and Antibacterial Behavior, J. Materials, 1096(2018)1-15.

DOI: 10.3390/ma11071096

Google Scholar

[18] Saja A. Muhsin, Paul V. Hatton, Anthony Johnson, Nuno Sereno, Duncan J. Wood, Determination of Polyetheretherketone (PEEK) mechanical properties as a denture material, J. The Saudi Dental, 31 (2019) 382-391.

DOI: 10.1016/j.sdentj.2019.03.005

Google Scholar

[19] ASTM D695-15 Standard Test Method for Compressive Properties of Rigid Plastics (ASTM International) West Conshohocken, PA, (2015).

Google Scholar

[20] Y. Torres, J. J. Pavón, and J. a. Rodríguez, Processing and characterization of porous titanium for implants by using NaCl as space holder, J. Mater. Process. Technol., 212(2012)1061–1069.

DOI: 10.1016/j.jmatprotec.2011.12.015

Google Scholar

[21] M. P. N. Poondlaa, T.S. Srivatsanb, A. Patnaika, A study of the microstructure and hardness of two titanium alloys: Commercially pure and Ti–6Al–4V, J. Alloys Compd., 486(2009)162–167.

DOI: 10.1016/j.jallcom.2009.06.172

Google Scholar

[22] Y. Kawai, H. Murakami, B. Shariati, E. Klemetti, J. Blomfield, L. Billette, J. Lund, J. Fein., traditional techniques produce better conventional complete dentures than simplified techniques. Journal of Dentistry. 33(2005)659-668.

DOI: 10.1016/j.jdent.2005.01.005

Google Scholar