The Experimental Study of Thermodynamic Performance on R407C Air-Conditioner Hot Water Combined Unit

Article Preview

Abstract:

This paper analysis on the design and the test of an air-conditioner hot water combined unit using environmental friendly refrigerant R407C. Firstly the research status of the system is elaborated for air-source heat pump water heater simply. Then the principle and structure are described on an air-conditioner heat pump followed by a water heater at different running modes and different operation conditions. The hot water experiments of the unit in three seasons have been tested and researched in a multi-functional environmental chamber. Some analysis of the unit’s thermodynamic performance is carried out from the test data for improving such kind of machine afterward.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 467-469)

Pages:

549-553

Citation:

Online since:

February 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wentao Tang, Design of Domestic Air Source Heat Pump Water Heater. Gas & Heat, No. 1, (2007), p.12.

Google Scholar

[2] Shengruan Wang, etal, The Performance Experiment of Air-source Heat Pump Water Heater Working in Winter, Refrigeration, No. 3, (2007), p.47.

Google Scholar

[3] Jinping Liu, Experiments on The Transient Thermal Behavior of Water Reservoir of a Heat Pump Water Heater. Acta Energiae Solaris Sinica, Vol. 28, No. 5(2007), p.472.

Google Scholar

[4] Qiang Ding, Research and Design of a Performance Test Device for Heat pump Water Heater. Computer Mesaurement & Control, (2007), p.23.

Google Scholar

[5] YaoYang, Development and Solution of Mathematical Model for Air-source Heat Pump Water Chiller/Heaters under Frosting. Journal of Hunan University (Natural Sciences), Vol. 33, No. 1, (2006).

Google Scholar

[6] Bin Jiang, Performance Analysis of an Air-source Heat Pump Water Heater under Variable Conditions. Heating Ventilating & Air Conditioning, No. 4 (2007), p.35.

Google Scholar

[7] Fang Wang, Development and Analysis on A Multifunction Man-made Environment Laboratory. Refrigeration & Air-condition, No. 3 (2005), p.74.

Google Scholar

[8] Weimon Yan, Hungyi Li, Performance of finned tube heat exchangers under frosting conditions. International Journal of Heat and Mass Transfer, Vol. 46 (2003), p.871.

DOI: 10.1016/s0017-9310(02)00346-0

Google Scholar