A Critical Assessment of the Four Basic Methods of Tomographic Imaging

Article Preview

Abstract:

Τhe incidence of and mortality from cancer have been increasing steadily for the past 50 years. Most cancers are not localized when first detected, but early detection is mandatory to improve prognosis. In this article, we performed a comparison of four basic methods of tomographic imaging, Positron emission tomography (PET), the computerized tomography (CT), Magnetic Resonance Imaging (MRI) scanner and the ultrasound scanner (US), in respect to their advantages and disadvantages.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

657-660

Citation:

Online since:

April 2014

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] DS Vlachos, DK Fragoulis, JN Avaritsiotis An adaptive neural network topology for degradation compensation of thin film tin oxide gas sensors, Sensors and Actuators B: Chemical, 45, 3, p.223–228, (1997)

DOI: 10.1016/s0925-4005(97)00309-2

Google Scholar

[2] CA Papadopoulos, DS Vlachos, Effect of surface catalysts on the long-term performance of reactively sputtered tin and indium oxide gas sensors, Sensors and Actuators B: Chemical 42, 2, p.95–101, (1997)

DOI: 10.1016/s0925-4005(97)00190-1

Google Scholar

[3] I. Giouroudi, A. Ktena and E. Hristoforou, Microstructural characterization of cylindrical Fe1-xNix thin films, J. Opt. Adv. Mat., 6, pp.45-50, (2004)

Google Scholar

[4] E. Hristoforou, Amorphous Magnetostrictive Wires Used in Delay Lines for Sensing Applications, J. Magn. Magn. Mater., 249, pp.387-392, (2002)

DOI: 10.1016/s0304-8853(02)00563-2

Google Scholar

[5] E. Hristoforou, A. Ktena, Magnetostriction and magnetostrictive materials for sensing applications, J. Magn. Magn. Mater., 316, pp.372-378, (2007)

DOI: 10.1016/j.jmmm.2007.03.025

Google Scholar

[6] E. Hristoforou and D. Niarchos, Mechanical Sensors Based on Re-Entrant Flux Reversal, IEEE Trans. Mag., 28, pp.2190-2192, (1992)

DOI: 10.1109/20.179439

Google Scholar

[7] P. D. Dimitropoulos, J. N. Avaritsiotis and E. Hristoforou, A novel micro-Fluxgate sensor based on the AMR effect of ferromagnetic film-resistors, Sensors and Actuators A, 107, pp.238-247, (2003)

DOI: 10.1016/s0924-4247(03)00378-9

Google Scholar

[8] B. Dufay, S. Saez, C. Cordier, C. Dolabdjian, C. Dubuc, E. Hristoforou, S. Ubizskii, 2D hybrid yttrium iron garnet magnetic sensor noise characterization, IEEE Sensors Journal (12), art. 5873114, pp.3211-3215, (2011)

DOI: 10.1109/jsen.2011.2159372

Google Scholar

[9] C. Petridis, I Petrou, PD Dimitropoulos, E Hristoforou, Determining appropriate magnetic core properties for a new type of flux-gate like sensor, Sensor Letters, 5, pp.98-101, (2007)

DOI: 10.1166/sl.2007.072

Google Scholar

[10] P. Dimitropoulos, J.N. Avaritsiotis, E. Hristoforou, Boosting the Performance of Miniature Fluxgates With Novel Signal Extraction Techniques, Sensors and Actuators A, 90, pp.56-72, (2001)

DOI: 10.1016/s0924-4247(01)00452-6

Google Scholar

[11] E. Hristoforou, H. Hauser and PD Dimitropoulos, On a New Principle of Smart Multi-Sensor Based on Magnetic Effects, IEEE Sensors, 6, pp.372-379, (2006)

DOI: 10.1109/jsen.2005.859781

Google Scholar

[12] C. Petridis, A. Ktena, E. Laskaris, PD Dimitropoulos, E Hristoforou, Ni-Fe thin film coated Cu wires for field sensing applications, Sensor Letters, 5, pp.93-97, (2007)

DOI: 10.1166/sl.2007.071

Google Scholar

[13] E. Hristoforou, New monolithic three dimensional field sensors with high sensitivity, J. Opt. Adv. Mat., 8, pp.1691-1697, (2006)

Google Scholar

[14] J. Petrou, P. D. Dimitropoulos and E. Hristoforou, New 2-D Fluxgate Devices Based on the Phase Modulation of Magnetization Rotation in AMR Films, Sensors and Actuators A, 129, pp.107-111, (2006)

DOI: 10.1016/j.sna.2005.11.032

Google Scholar

[15] C. Petridis, PD Dimitropoulos, E. Hristoforou, New Magnetic Field Sensor Based on Combined Flux-Gate/Hall-Effect Arrangement, IEEE Sensors Journal, 9, pp.128-134, (2009)

DOI: 10.1109/jsen.2008.2011083

Google Scholar

[16] I Petrou, P Skafidas, E Hristoforou, Electronic toll and road traffic monitoring system using 3-D field AMR sensors, Sensor Letters, 11, pp.91-95, (2013)

DOI: 10.1166/sl.2013.2787

Google Scholar

[17] P.D. Dimitropoulos, G.I. Stamoulis, E. Hristoforou, A 3-d hybrid Jiles-Atherton/Stoner-Wohlfarth magnetic hysteresis model for inductive sensors and actuators, IEEE Sensors Journal, 6, pp.721-736, (2006)

DOI: 10.1109/jsen.2006.874454

Google Scholar

[18] E. Bernardi, A. Lascialfari, A. Rigamonti, L. Romano, V. Iannotti, G.Ausanio, C. Luponio, "Zero-dimensional superconducting fluctuations and fluctuating diamagnetism in lead nanoparticles", Phs. Rev. B, 74

DOI: 10.1103/physrevb.74.134509

Google Scholar

[19] Rohren, E.M., T.G. Turkington, and R.E. Coleman, Clinical applications of PET in oncology. Radiology, 231(2): pp.305-32, (2004)

DOI: 10.1148/radiol.2312021185

Google Scholar

[20] Grierson, J.R., et al., A radiosynthesis of fluorine-18 fluoromisonidazole. J Nucl Med, 30(3): pp.343-50, (1989)

Google Scholar

[21] Blodgett, T.M., C.C. Meltzer, and D.W. Townsend, PET/CT: form and function. Radiology, 242(2): pp.360-85, (2007)

DOI: 10.1148/radiol.2422051113

Google Scholar

[22] Buchbender, C., et al., Oncologic PET/MRI, part 1: tumors of the brain, head and neck, chest, abdomen, and pelvis. J Nucl Med, 53(6): pp.928-38, (2012)

DOI: 10.2967/jnumed.112.105338

Google Scholar