Lateral Resolution Test for Confocal Laser Scanning Microscope

Article Preview

Abstract:

To meet the performance test for the confocal laser scanning microscope (CLSM) accurately in some specific application occasions, the spatial resolution imaging principle of confocal laser scanning microscope was analyzed theoretically. And the micron line spacing as the measurement standard has tried to investigate the lateral resolution of CLSM in experiment. The value range of the lateral resolution was calculated by the fluctuation state of the output light intensity signal when there is the lateral movement between the objective with sample. At the same time, some reasons for spatial resolution are also been evaluated in theory. Experiments demonstrate that if the value of the line spacing standard is closer to the spatial resolution of CLSM, the standard can be utilized to test the spatial resolution. So we can use a a series of lines spacing standards with different lines spacing values to test the serial effective resolution. And in our experiment, we only measured line spacing standard with 8μm line width and 100μm line pitch with many times by CLSM, and the spatial resolution of the CLSM is obtained about more minimal than 0.3μm by the scanning curves.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 609-610)

Pages:

1159-1164

Citation:

Online since:

April 2014

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] E. Ahrent, Optical Metrology Made Easy, Imaging & Microscopy. 11(2009), 20-21.

DOI: 10.1002/imic.200990031

Google Scholar

[2] S. T. Hess, T. P. Girirajan, and M. D. Mason, Ultra-high resolution imaging by fluorescence photoactivation localization microscopy, Biophys. J. 91(2006), 4258-4272.

DOI: 10.1529/biophysj.106.091116

Google Scholar

[3] J. Kim, D. C. Kim, and S. H. Back, Demonstration of high lateral resolution in laser confocal microscopy using annular and radially polarized light, Microsc. Res. Tech. 72(2009), 441-446.

DOI: 10.1002/jemt.20689

Google Scholar

[4] Y. Kozawa, T. Hibi, A. Sato, H. Horanai, M. Kurihara, N. Hashimoto, H. Yokoyama, T. Nemoto, and S. Sato, Lateral resolution enhancement of laser scanning microscopy by a higher-order radially polarized mode beam, Opt. Express. 19(2011).

DOI: 10.1364/oe.19.015947

Google Scholar

[5] O. Haeberlé and B. Simon, Saturated structured confocal microscopy with theoretically unlimited resolution, Opt. Commun. 282(2009), 3657-3664.

DOI: 10.1016/j.optcom.2009.06.025

Google Scholar

[6] R.K. Leach, Optical measurement of surface topography. Springer, Berlin (2011).

Google Scholar

[7] E. Heurich , M. Beyer , K. D. Jandt, J. Reichert, V. Herold , M. Schnabelrauch, & B. W. Sigusch,  Quantification of dental erosion-a comparison of stylus profilometry and confocal laser scanning microscopy (CLSM), Dental Materials. 26 (2010).

DOI: 10.1016/j.dental.2009.12.001

Google Scholar

[8] R. Kasper, B. Harke, C. Forthmann, P. Tinnefeld, S. W. Hell, and M. Sauer, Single-molecule STED microscopy with photostable organic fluorophores, Small. 6(2010), 1379-1384.

DOI: 10.1002/smll.201000203

Google Scholar

[9] R. Fiolka, L. Shao, E. H. Rego, M. W. Davidson, and M. G. Gustafsson, Time-lapse two-color 3D imaging of live cells with doubled resolution using structured illumination, Proc. Natl. Acad. Sci. U.S.A. 109(2012), 5311-5315.

DOI: 10.1073/pnas.1119262109

Google Scholar

[10] A. Fujii, H. Suzuki, K. Yanagi, Development of measurement standards for verifying functional performance of surface texture measuring instruments. J. Phys.: Conf. Ser. 311 (2011), 012009.

DOI: 10.1088/1742-6596/311/1/012009

Google Scholar

[11] S. A. Jones, S. H. Shim, J. He, and X. Zhuang, Fast three-dimensional super-resolution imaging of live cells, Nat. Methods. 8(2011), 499-505.

DOI: 10.1038/nmeth.1605

Google Scholar