Research on Rapid Detection and Accounting of Small Particles in Marine Hydraulic Oil

Article Preview

Abstract:

Hydraulic system is widely used in the ship, when the diameter of tiny particles in hydraulic oil exceeds 20μm it indicates that the abnormal wear occurred and the malfunction may cause. This paper uses the light blockage method, the microfluidic detection chip for hydraulic oil detection has been designed and fabricated, a simple and effective optical detection system is developed with the signal amplification and data collection to achieve the detection of tiny particles, and finally through the JAVA programming to count the number of particles in which the diameter is more than 20μm. The results of rapid detections on iron particles with diameter between 25μm and 38μm show the good performance of the detection system and prove that the method is feasible.

You might also be interested in these eBooks

Info:

Periodical:

Key Engineering Materials (Volumes 645-646)

Pages:

687-692

Citation:

Online since:

May 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Ge Wang, Dongfeng Liu, Xinfa Shi. Marine hydraulic oil monitoring technology research status [J]. Lubricate oil, 2013, 04: 38-41.

Google Scholar

[2] Shiyou Wu, Shufang Wang. The sources and harm of hydraulic oil pollution and its control measures [J]. Equipment Manufacturing Technology, 2008, 03: 80-82.

Google Scholar

[3] Tucker Je, Galie Tr, Schultz A, et al. Lasernet Fines Optical Wear Debris Monitor a Navy Shipboard Evaluation of Cbm Enabling Technology[C]. 54th Mach Fail Prev Technol Proc, 2000: 191.

Google Scholar

[4] Xiaoying Zeng, Yunhua Li. Using the image measuring method of oil pollution of online monitoring and prediction [J]. Pneumatic and hydraulic pressure seal.

Google Scholar

[5] Yang Li, Zheng Yingna, Wang Renhuang. Experimental Study and the Theoretical Model of Optical Flowmeter of Solid Debris[J]. Mechanical Engineering, 2004, 8: 160-165.

Google Scholar

[6] Qian Tian. Window type automatic particle counting method to determine oil pollution in the hydraulic system [J]. Intelligence development of science and technology and economy, 2003(5): 109-110.

Google Scholar

[7] Huanxiao Wen, Fu Jingye. Light resistance method to measure the oil particle pollution in the study[J]. The space measuring technology, 2002(6): 38-41.

Google Scholar

[8] Dongqing Li. Microfluidic lab-on-a-chip devices for biomedical applications[J]. Microfluidics Based Microsystems: Fundamentals and Applications. 2010: 377-396.

Google Scholar

[9] Wen Huang. Ship sewage rapid detection method for basic research. Master's thesis. Da Lian Maritime University. (2012).

Google Scholar

[10] Bingcheng Lin, Jianhua Qin. Microfluidic chip laboratory[J]. The chromatographic. 2005. 09: 456-463.

Google Scholar

[11] Tao Xu, Yucheng Gao, Xing Wu. For now method in principle analysis of the small particle size of particle detection[J]. Journal of instrument, 2005, 01: 13-16+22.

Google Scholar