Mechanical Aspects of Self-Alignment Mechanism in Hip Bipolar Hemiarthroplasty

Article Preview

Abstract:

The paper proposes a mechanical study of the self-centering mechanism of the bipolar prosthesis. This represents the fundamental principle of the bipolar construction, and relays on the offset between the inner and outer center of rotations of the bipolar head. In the paper, the kinematical aspects of the construction were recorded and explained by using five different offset values and keeping constant the femoral head diameter and the acetabular diameter. The simulations were conducted by imposing to the femoral head a linear movement in the vertical direction, similar to a reaction force that occurs when an implanted patient stands up. Two initial conditions were used for each geometric offset: one ideal, no friction and another more realistic by implementing friction coefficients at the sliding interfaces.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

81-86

Citation:

Online since:

August 2017

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2017 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] S.S. Mohanty, H. Garg, Self centering mechanism in bipolar endoprosthesis – is it effective?, Orthopaedic Proceedings 92 (2010).

Google Scholar

[2] S.M. Rowe, J.Y. Chung, E.S. Moon, T.R. Yoon, H.Y. Seo, J. J Lee, Why does outer joint motion predominate in bipolar hip prosthesis? Experimental and clinical studies, Acta Orthop Scand. 75(2004) 701-708.

DOI: 10.1080/00016470410004067

Google Scholar

[3] M.S. Lee, A.C. Chen, C.H. Kuo C.L. Tai, V. Senan , C.H. Shih, The position of the bipolar cup reflects the direction of the hip contact force acting on it, J Arthroplasty. 22(2007) 189-194.

DOI: 10.1016/j.arth.2006.02.079

Google Scholar

[4] H. Tsumura, N. Kaku, T. Torisu, Does the self-centering mechanism of bipolar hip endoprosthesis really work in vivo?, Journal of Orthopaedic Surgery 13(2005) 46-51.

DOI: 10.1177/230949900501300108

Google Scholar

[5] S.M. Rowe, J.Y. Chung, T.R. Yoon, H.Y. Seo, J.J. Lee, M.S. Kim, Experimental and Clinical Motion Analysis of the Bipolar Hip Prosthesis, J. of Korean Orthop. Assoc. 38(2003) 454-460.

DOI: 10.4055/jkoa.2003.38.5.454

Google Scholar

[6] Y. Tsukamoto, K. Mabuchi, T. Futami, D. Kubotera, Motion of the bipolar hip prosthesis components, Acta Orthop. Scand. 63(1992) 648-652.

DOI: 10.3109/17453679209169728

Google Scholar

[7] S.W. Krein, E.Y. Chao, Biomechanics of bipolar hip endoprostheses, J. Orthop. Res. 2(1984) 356-368.

DOI: 10.1002/jor.1100020408

Google Scholar

[8] J.Y. Lazennec, A. Brusson, M.A. Rousseau, All ceramic tripolar THA to prevent dislocations in risky patients, Orthopedics, Physical Medicine and Rehabilitation Arthroplasty-Update, open access - INTECH (2013).

DOI: 10.5772/53251

Google Scholar

[9] D. Vermeșan, R. Prejbeanu, H. Hărăguș, M. Ahmadi, G. Damian, Metallosis during partial component hip revision arthroplasty, Rev. Chim. 63(2012) 953-955.

Google Scholar