Determination of the Content of Fluorine and Chlorine in Inorganic Insulation Materials by Ion Chromatography

Article Preview

Abstract:

A fast and accurate method for simultaneous determination of the content of fluorine and chlorine in inorganic thermal insulation materials by ion chromatography was developed. The samples were cut into pieces of weight less than 40mg, washed with water as the extractant, heated for 30 min and then centrifuged, filtered through a 0.22 μm microporous membrane, and the cation was removed using a SEP-H column. The solution was rinsed with 20/30 mM KOH as the mobile phase, separated by anion exchange column and then detected using a conductivity detector. The mass concentration of fluorine and chlorine in the range of 0.1-10mg/L was linearly related to their peak area, the detection limit of fluorine was 0.030mg/Land the detection limit of chlorine was 0.016mg/L. The relative standard deviations (n=6) of the three typical inorganic insulating materials (glass wool, rock wool and mineral wool) were less than 2.0% and the rate of recovery of fluoride and chloride ion was between 97% and 101%.The method had good accuracy and recovery rate. The absolute error of the measured value between ion chromatography and the national standard was less than 0.20%.The results showed that the method was suitable for the determination of the content of fluorine and chlorine in inorganic thermal insulation materials

You might also be interested in these eBooks

Info:

Periodical:

Pages:

41-45

Citation:

Online since:

April 2018

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2018 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] J.G. Song, Y.H. Liu, L.Y. Chen.Current research status and development of thermal insulating materials in the world[J].Materials Review ,2010,24(5):378-380.

Google Scholar

[2] Y.Q. Liang.A study on thermal insulation materials on exterior walls[J].Urbanism andArchitecture,2012(1):106-107.

Google Scholar

[3] S.H. Fan, W.Z. Wang. The Probe of corrosion leakage in welding seam by chloride ion of austenitic stainless steel 304 pipe[J]. CC&AC,2014(2):73-76.

Google Scholar

[4] S.G. Qian, G.You.The analysis of corrosion cause of austenitic stainless steel (1Cr18Ni9Ti) tubular product in media containing chloride ion[J].Guizhou Chemical Industry,2012,37(2):25-29.

Google Scholar

[5] GB/T17393-2008, Specification for thermal insulation for use in contact with austenitic stainless steel[S].

Google Scholar

[6] JC/T 618-2005,Methods of chemical analysis of thermal insulation materials for leachable chloride, fluoride, silicate and sodium Ions[S].

DOI: 10.1520/c0871-08

Google Scholar

[7] D.H. Xu, Y.F. Mei, S.H. Liu. Simultaneous determination of fluorine and chlorine in gypsum and gypsum products by ion chromatography[J].Inspection and certification,2014 ,30(3):1-2.

Google Scholar

[8] D.H. Xu, P.Chen, S.H. Liu.Ion chromatography for the continuous determination of sulfite and sulfide in gypsum and gypsum products[J].Key Engineering Materials,2016,12:75-79.

DOI: 10.4028/www.scientific.net/kem.726.75

Google Scholar

[9] L. Wang, X.B. Xiang, H. Wang.IC Determination of 6 anions in rubber and plastic thermal insulation materials [J].PTCA(PART B:CHEM ANAL),2015,51(12):1698-1700.

Google Scholar

[10] G.Q. Li, Y.L. Li, Z.H. Liang. Determination of 4 anions in the waste acid cleaning solution by ion chromatography[J].Chinese JournalofSpectroscopyLaboratory.2012,29(3):982-984.

Google Scholar

[11] P.J. Xie, J.Y. Sun, L.M. Wang. Determination of trace anions in high-purity hydrofluoric acid by capillary ion chromatography with column-switching technique[J].Chinese Journalof Inorganic Analytical Chemistry,2012 ,2(3):28-30.

Google Scholar

[12] X. liu, Y.L. Shi,W. Wang.Determination of tracedisinfection by products dichloroacetic acid and trichloroacetic acid in tap water by ion chromatography electrospray tandem mass spectrometry[J].Chinese Journal of Analytical Chemistry,2007,35(2):221-226.

Google Scholar

[13] L. Wang, W.W. Bian, H. Wang. Determination of chloride content in elastomeric thermal insulation materials by ion chromatography[J]. Analytical Instruments,2014,(5)40-43.

Google Scholar