Inertial Flow Phenomenon Analysis on Piezoelectric Pump

Article Preview

Abstract:

The author finds that there is outflow during piezoelectric pump sucking process, and a dynamic model combined with hydrodynamics and mechanical vibration is presented for the anlysis of piezoelectric pump sucking process phenomenon. The model is utilized to study the reason of sucking process outflow and the effect of the driving frequency, outlet valve rigidity, the load in inlet and outlet on the sucking process outflow. The result turns out that the flow inertia is the cause of sucking process outflow; the inertial flow also exists during draining process as the sucking process; increasing driving frequency, or outlet valve rigidity, the inertial flow decreases, increasing the load in inlet and outlet has the same effect. The research makes it clear that the pump output flow should include two parts, bulk flow and inertial flow, which will provide theory reference for the precise flow control of piezoelectric pump.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

920-926

Citation:

Online since:

October 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] KAN J W, CAO R Q, YANG Z G, etc. Structure design and performance analysis of a piezoelectric pump [J]. Optics and Precision Engineering, 2002, 24(5): 368-371. (in Chinese).

Google Scholar

[2] KAN J W, YANG Z G, HUA S M, CHENG G M. Study on performance of a check-valved piezoelectric pump [J]. Transactions of the Chinese Society of Agricultural Machinery, 2003, 34(5): 84-87. (in Chinese).

Google Scholar

[3] CHENG G M, YANG Z G, ZENG P, etc. Research on the chamber volume fluctuations of piezoelectric pump [J]. Piezoelectrics & Acorstooptics, 1998, 20(6): 389-392. (in Chinese).

Google Scholar

[4] LIU G J, CHENG G M, YANG Z G. Experimental research on a piezoelectric micro-pump for precision pumping[J]. Optics and Precision Engineering, 2006, 14(4): 612-616. (in Chinese).

Google Scholar

[5] SPENCER W J, WAYNE T, CORBETT L R. An electronically controlled piezoelectric insulin pump and valves[J]. Transactions on Sonics and Ultrasonics, 1978, 25(3): 153-156. (in Chinese).

DOI: 10.1109/t-su.1978.31006

Google Scholar

[6] KAN J W, YANG Z G, TANG K H. Pumping performance of a new piezoelectric pump for drug delivery[J]. Journal of Biomedical Engineering, 2004, 21(2): 297-301. (in Chinese).

Google Scholar

[7] E. John Finnemore, Joseph B. Franzini. Fluid mechanics with engineering applications[M]. Beijing, China Machine Press (in Chinese).

Google Scholar

[8] Bo Lia, Quanfang Chen, Dong-Gun Lee, Jason Woolman, Greg P. Carman, Development of large flow rate, robust, passive micro check valves for compact piezoelectrically actuated pumps[J]. Sensors and Actuators A, 2005, 117(2): 325-330.

DOI: 10.1016/j.sna.2004.06.029

Google Scholar

[9] Satyajit Kar, Scott McWhorter, Sean M. Ford and Steven A. Soper. Piezoelectric mechanical pump with nanoliter per minute pulse-free flow delivery for pressure pumping in pulse-free flow delivery for pressure pumping in micro-channels[J]. Analyst, 1998, 123(6): 1435-1441.

DOI: 10.1039/a800052b

Google Scholar

[10] Jung-Ho Park, Kazuhiro Yoshida, Shinichi Yokota. Resonantly driven piezoelectric micropump fabrication of a micropump having high power density[J]. Mechatronics, 1999, 9: 687-702.

DOI: 10.1016/s0957-4158(99)00028-8

Google Scholar

[11] Van Thanh Dau , Thien Xuan Dinh, Tanaka Katsuhiko, Sugiyama Susumu. A cross-junction channel valveless -micropump with PZT actuation[J]. Microsyst Technol, 2009, 15: 1039-1044.

DOI: 10.1007/s00542-009-0878-2

Google Scholar

[12] Ching-Jiun Lee, Horn-Jiunn Sheen, Zhi-Kai Tu , U. Lei, Cheng-Ying Yang. A study of PZT valveless micropump with asymmetric obstacles[J]. Microsyst Technol, 2009, 15: 993-1000.

DOI: 10.1007/s00542-009-0839-9

Google Scholar

[13] Hsien-Tsung Chang, Chih-YungWen , Chia-Yen Lee. Design, analysis and optimization of an electromagnetic actuator for a micro impedance pump[J]. Journal of Micromechanics and Microengineering, 2009, 19: 1-12.

DOI: 10.1088/0960-1317/19/8/085026

Google Scholar

[14] Y. C. Hsu XXX N. B. Le. Equivalent electrical network for performance characterization of piezoelectric peristaltic micropump[J]. Microfluid Nanofluid, 2009, 7: 237-248.

DOI: 10.1007/s10404-008-0380-7

Google Scholar

[15] Yi-Chu Hsu, Jia-Long Hsu , Ngoc Bich Le. An experimental and numerical investigation into the effects of the PZT actuator shape in polymethylmethacrylate (PMMA) peristaltic micropumps[J]. Microsyst Technol, 2009, 15: 565-571.

DOI: 10.1007/s00542-008-0761-6

Google Scholar