Failure Analysis and Transformation of Hydrogen Compressor Dry Gas Seal

Article Preview

Abstract:

Recycle hydrogen compressor group is the core equipment of heavy coker gas oil hydrotreater unit of refinery. This compressor adopts tandem structure with intermediate labyrinth seal as its dry gas seal type. The compressor dry gas seal has officially been put into operation for six months, it damaged twice and caused the device to unplanned shutdown, seriously affected the long term operation of the device. During research and analysis on the seal of the unit, a series of problems were found, such as gas anti-channeling, sealing gas with oil etc. After transformation on the sealed gas supply system, the compressor achieved the purpose of long term stable running.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

98-101

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] C.J. Lin: Machine Pump Maintenance Fitter (China Petrochemical Press, in Chinese,2008)

Google Scholar

[2] L.Wei:Chemical Sealing Practical Technology(Chemical Industry Press,in Chinese,2011).

Google Scholar

[3] Paul C.Hanlon: Compressor Handbook(McGraw-Hill Companies, 2001).

Google Scholar